Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Issued
Type:
Commercial Building
Address NEW:
990 E VALENCIA RD
Apply Date:
04/19/2021
Applicant:
Description:
Instrumentation/control upgrade including new vault and control building.CDRC indicated that no Spe

Permit Reviews

Permit Number - T21CM03291
Permit Status: Issued
Permit Description: Instrumentation/control upgrade including new vault and control building.CDRC indicated that no Spe
Start Date Submittal Complete Date Status  
04/19/2021 COMMERCIAL - TI 06/03/2021 COMPLETED Review Details
06/03/2021 COMMERCIAL - TI 07/19/2021 COMPLETED Review Details
08/16/2021 RESUBMITTAL 08/26/2021 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T21CM03291
Permit Status: Issued
Permit Description: Instrumentation/control upgrade including new vault and control building.CDRC indicated that no Spe
Total Outstanding Activity Conditions - 6
Date Name
05/04/2021 SPECIAL INSPECTION FORMS AND REPORTS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY.
05/04/2021 SPECIAL INSPECTION FOR CONCRETE IS REQUIRED..
05/04/2021 SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED.
05/04/2021 SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED.
06/15/2021 SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED.
06/15/2021 SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED.

Outstanding Inspections

Permit Status: Issued
Permit Number: T21CM03291
Permite Description: Instrumentation/control upgrade including new vault and control building.CDRC indicated that no Spe
Total Outstanding Inspections - 7
Last Inspection Date Description Inspector Results Comments
04/05/2022 COT - LCEL - Temporary Service N/A Canceled {Activity date: 04/05/2022; Status: Not Applicable; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - not applicable
}
11/04/2022 COT - LCBU - Building Final N/A Canceled Inspection Canceled
11/04/2022 COT - LCME - Mechanical Final N/A Canceled Inspection Canceled
11/04/2022 COT - LCEL - Outdoor Lighting N/A Canceled Inspection Canceled
11/04/2022 COT - FCON - Fire - Final N/A Canceled Inspection Canceled
11/04/2022 COT - LCME - Mechanical Intermediate N/A Canceled Inspection Canceled
11/07/2022 COT - LCEL - Electrical Underground N/A Canceled Inspection Canceled

Completed Inspections

Permit Status: Issued
Permit Number: T21CM03291
Permit Description: Instrumentation/control upgrade including new vault and control building.CDRC indicated that no Spe
Total Completed Inspections - 13
Date Description Inspector Results Comments
01/13/2022 COT - LCEL - Grounding/Bonding Passed {Activity date: 01/13/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved, EGC connections to ground ring for control room equipment complete.
} ; {Activity date: 01/03/2022; Status: Approved; Inspector: TGAUSP; Comment: Entered by VVERA1 - Approved, 3-O copper ring and grid}
01/25/2022 COT - LCBU - Excavation/Rebar/Zoning Passed {Activity date: 01/25/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved, Control room slab re enforcement installed and ok for concrete placement.} ; {Activity date: 01/13/2022; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - PARTIAL, Inspection for Control Room footings F1, OK for concrete placement. Note: required special inspection report for Masonry Control Joints that were missing, and spoil clean out prior to concrete.}
01/25/2022 COT - LCBU - Preslab Passed {Activity date: 01/25/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved, Control room slab ok for concrete placement.} ; {Activity date: 01/13/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - NOT READY.
}
02/02/2022 PDSD Building Division - TEP PM Clearance Passed {Activity date: 02/02/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - CODE ECO}
02/02/2022 COT - LCEL - Construction Power Passed {Activity date: 02/02/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved, clear TEP ECO}
04/05/2022 COT - LCBU - Stem Wall/Retaining Wall Passed {Activity date: 04/05/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved}
04/05/2022 COT - LCEL - Electrical Progress Passed {Activity date: 04/05/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved}
04/05/2022 COT - LCEL - Electrical Intermediate Passed {Activity date: 04/05/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 03/11/2022; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Partial, Inspection of Booster Control panels, Feeders, and PLC Connections-in Control room ok to proceed.

}
04/05/2022 COT - LCBU - Framing Passed {Activity date: 04/05/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved}
04/05/2022 COT - LCEL - Electrical Above Ceiling Passed {Activity date: 04/05/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved}
04/05/2022 COT - LCBU - Building Progress Passed {Activity date: 04/05/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved}
04/05/2022 COT - LCBU - Masonry Pregrout Passed {Activity date: 04/05/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved}
11/04/2022 COT - LCEL - Electrical Final Passed Approved, pending all other final inspections