Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T21CM00405
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/25/2021 | DTRAMME1 | ENGINEERING | REVIEW | Passed | |
| 01/27/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Specify that all owner furnished plumbing fixtures shall be listed by a third-party certification agency as complying with the relevant standards. Reference: Section 303.4, IPC 2018. 2. The fixture drain serving an automatic clothes washer shall connect to a fixture branch that is at least 3 inches in diameter. Reference: Section 406.2, IPC 2018. 3. Clarify how the new lavatory fixture has been vented in accordance with one of the methods shown in the IPC. Reference: Section 901.2.1, IPC 2018. |
| 01/27/2021 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Coordinate the plumbing and mechanical drawings with regard to the tag name of the new rooftop AC unit. Reference; Section 107.2.1, IBC 2018. 2. Ventilation for kitchens in private dwellings requires a minimum of 25 CFM (continuous operation) or 100 CFM (intermittent operation) of mechanical exhaust per room with no recirculation of air (e.g. specify the exhaust flowrate for the kitchen hood). Reference: Table 403.3.2.3, IMC 2018. |
| 01/27/2021 | ROBERT SHERRY | WATER | REVIEW | Passed | |
| 02/04/2021 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 02/08/2021 | JPEELDA1 | FIRE | REVIEW | Approved | |
| 02/08/2021 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 02/16/2021 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 02/16/2021 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed |