Plan Number: T20PI00026
Parcel: Unknown

Review Status: Completed

Review Details: PIA - SUBMITTAL

Plan Number - T20PI00026
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/14/2021 GARY WITTWER DOT LANDSCAPE REVIEW Approved
01/14/2021 RLEIGH1 UTILITY CLEARANCES COT STREETS DIVISION Needs Review
01/14/2021 ZELIN CANCHOLA DOT TRAFFIC REVIEW Reqs Change Provide street and stop signs per the Pima County and City of Tucson 2020 Signing and Pavement Marking Manual, which can be found at: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Transportation/Roadway%20Design/FINAL_PimaCounty_CityofTucson_SigningPavementMarkingManual2020_FirstEdition.pdf
01/14/2021 ERNIE ENCINAS DOT_ELEC REVIEW Approved
01/14/2021 JIM FEMLING DOT STREET MAINTENANCE REVIEW Approved
01/14/2021 RLEIGH1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Needs Review
01/14/2021 RICHARD LEIGH DOT ENGINEERING REVIEW Reqs Change January 14, 2020

SUBJECT: La Estancia Phase II, Offsite Parcel 4 Paving Plans

PROJECT REVIEWER: Richard Leigh, DTM Eng. Review

RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to resubmittal. Please include a response letter addressing the following comments.


1. Add the plan number "I-2020-029( in the title block of each sheet.

2. Add PIA activity number ā€œT20PI00026ā€ on coversheet.

3. Sheet 2: Paving Note 5 to indicate that the asphaltic concrete shall conform to PAG's Replacement Specification for Section 406 Asphaltic Concrete, dated December 12, 2019.

4. Sheet 2 through 10: Use current DTM title blocks. See Engineering Plan Template at: https://www.tucsonaz.gov/files/transportation/Engineering_Plan_Templates_Dec_2019.pdf

5. Sheet 5: Indicated placement of a driveway apron based on PAG SD 206 and removable post barricades for the basin ā€œCā€ maintenance access road.

6. Sheet 5: Provide a public access easement for the section of sidewalk that encroaches onto common area on the eastside of Camino Vita Azul between Sta. 10+47 and 12+50.

7. Provide street and stop signs per the Pima County and City of Tucson 2020 Signing and Pavement Marking Manual, which can be found at: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Transportation/Roadway%20Design/FINAL_PimaCounty_CityofTucson_SigningPavementMarkingManual2020_FirstEdition.pdf

8. Refer to redline drawings for additional comments and comment details.

If you have any questions, I can be reached at 520-237-8692 or emailed at Richard.Leigh@tucsonaz.gov.
01/14/2021 RLEIGH1 UTILITY CLEARANCES PC WASTEWATER MGMT Needs Review
01/14/2021 RLEIGH1 UTILITY CLEARANCES QUEST COMMUNICATION Needs Review
01/14/2021 RLEIGH1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Needs Review
01/14/2021 RLEIGH1 UTILITY CLEARANCES COX COMMUNICATION Needs Review
01/14/2021 RLEIGH1 UTILITY CLEARANCES SOUTHWEST GAS CORP Needs Review
01/14/2021 RLEIGH1 UTILITY CLEARANCES EL PASO NATURAL GAS Needs Review
01/14/2021 RLEIGH1 UTILITY CLEARANCES KINDER MORGAN ENERGY Needs Review
02/16/2021 RICHARD LEIGH PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed
02/16/2021 RICHARD LEIGH PIA COORDINATOR OUT TO CUSTOMER Completed