Permit Number: T20CM06818
Parcel: 101200370

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T20CM06818
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/07/2021 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Approved
01/07/2021 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
12/15/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Comment not resolved; the note on sheet A1.0 refers to the plumbing plans for information about the plumbed water cooler. Show the specifications on the plan set. [Initial comment: Provide specifications for the "plumbed water cooler" noted on sheet A1.0 (P6). The use of a point-of-use water dispenser in lieu of a drinking fountain requires the installation of a listed and labeled dispenser along with a permanently mounted disposable cup dispenser. The cup dispenser shall be located adjacent to the water dispenser with the dispensing end between 34" and 48" above the finished floor.]
12/15/2020 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Completed
12/16/2020 JPEELDA1 FIRE REVIEW Approved Per Tucson Water model dated 11-20-2020 they meet the fire flow requirements and do not require fire sprinklers.