Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T20CM04838
Parcel: 130052600

Address:
2334 S NORRIS AV

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM04838
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/06/2020 MALLORY RESS ZONING REVIEW Reqs Change ZONING REVIEW

RESUBMISSION OF REVISED PLANS AND COMMENT RESPONSE LETTER IS REQUIRED.

COMMENT: INCLUDE COMPLETE LOT COVERAGE CALCULATION ON SITE PLAN TO INCLUDE LOT SIZE AND LOT COVERAGE AS A PERCENTAGE

COMMENT:PROVIDE COMPLETE FLOORPLAN

COMMENT: PROVIDE TOP HEIGHT (UNDER ROOF) OF PROPOSED ADDITION FACING SOUTH PROPERTY LINE

COMMENT: CONFIRM THAT ELEVATIONS ARE LABELED ACCURATELY

COMMENT: SHOW EXISTING DETACHED ACCESSORY STRUCTURES ON SITE PLAN, INCLUDE SQUARE FOOTAGE, SETBACKS AND HEIGHT. IF STILL EXISTING THESE STRUCTURES NEED AT A MINIMUM ZONING COMPLIANCE AS IT DOES NOT APPEAR THEY HAVE BEEN PREVIOUSLY APPROVED AND DEPENDING ON SQUARE FOOTAGE THEY MAY REQUIRE INSPECTIONS.

QUESTIONS CONTACT MALLORY.RESS@TUCSONAZ.GOV
08/06/2020 MRESS1 ENGINEERING REVIEW Passed
08/06/2020 MRESS1 NPPO REVIEW Passed
08/06/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T20CM04838 R1
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

Consolidate pages of construction plans into a single .PDF file as prescribed at the PDSD web site. https://www.tucsonaz.gov/pdsd/online-permits Separate from support documents.

SITE PLAN:

1. Indicate the size of the yard water pipe to the building, R106.1.1. An undersized pipe will require updating for supporting the new demand.

SECTIONS - DETAILS:

1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38.

PLUMBING PLANS:

1. Provide the water pipe diameter between the meter and shut off valve in compliance with P2903.7. A minimum 1” service pipe is required for supplying water to more than 9.5 fixture units.

ELECTRICAL PLANS:

1. Update code references at the 8th note.
2. Show locations of each smoke alarm, R314. Notate the circuit number.
3. Smoke alarms are required outside each separate sleeping area, R314.3.2. Show a smoke alarm in each bedroom and outside in the immediate vicinity.

If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review