Permit Number: T20CM04361
Parcel: 125080060

Address:
2250 E 8TH ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM04361
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/10/2020 PC_JEDER1 NPPO REVIEW Passed
07/13/2020 PIMA COUNTY BUILDING-RESIDENTIAL REVIEW Reqs Change T20CM04361
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

STRUCTURAL PLANS:

1. Provide a complete braced wall (BW) design, R602.10 include a braced wall panel within 10’ of each end and no more than 20’ between edges with minimum total length of bracing determined by method and wall line spacing, Table R602.10.3(1);
or provide an engineer’s calculation, report and seal for a performance design.

SECTIONS - DETAILS:

1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38.

ELECTRICAL PLANS:

1. Show receptacle outlets at each kitchen counter space wider than 12” with no point along the wall line more than 24” from a receptacle outlet, E3901.4.1. Show receptacles within 2’ of counter edges or corners and no more than 4’ apart.

OUTDOOR LIGHTING CODE

1. Show the proposed fixture as full cut-off FCO style, or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. Adjustable security light fixtures are unshielded, not FCO.

If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
08/03/2020 ALEXANDRA HINES ZONING REVIEW Reqs Change 1. Provide dimension from east property line to proposed addition.
2. Show all detached existing structures and dimensions. If proposed for demo, keynote accordingly.
3. Provide sheets in plan set as 3 pages in 1 PDF file, not one page.

Alexandra Hines
alexandra.hines@tucsonaz.gov
5208376975
08/03/2020 AHINES2 ENGINEERING REVIEW Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
08/28/2020 VLEON1 APPROVAL SHELF Completed
08/28/2020 VLEON1 OUT TO CUSTOMER Completed
08/28/2020 VLEON1 REJECT SHELF Completed