Plan Number: T19SE00017
Parcel: Unknown

Review Status: Active

Review Details: REZONING - ZE HEARING

Plan Number - T19SE00017
Review Name: REZONING - ZE HEARING
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
06/19/2019 ANY DOT ENGINEERING REVIEW Active
06/19/2019 ANY ENV SVCS REVIEW Active
06/19/2019 ANY TUCSON WATER NEW AREA DEVELOPMENT REVIEW Active
06/19/2019 Any REZ AGENCY REVIEW PARKS & RECREATION Active
06/19/2019 Any REZ AGENCY REVIEW OFFICE OF CONSERVATION & SUSTAINABLE DEVELOPMENT Active
06/19/2019 Any REZ AGENCY REVIEW PIMA ASSN OF GOVTS Active
06/19/2019 Any REZ AGENCY REVIEW PIMA CNTY WASTEWATER Active
06/19/2019 Any REZ AGENCY REVIEW SCHOOL DISTRICT Active
06/19/2019 Any REZ AGENCY REVIEW ADOT Active
06/19/2019 Any REZ AGENCY REVIEW TDOT RTA Active
06/19/2019 Any REZ AGENCY REVIEW TDOT STREETS Active
06/19/2019 Any REZ AGENCY REVIEW OTHER AGENCIES Active
06/19/2019 ANY COMMUNITY PLANNING REVIEW Active
06/25/2019 MARTIN BROWN FIRE REVIEW Approved
06/25/2019 ELISA HAMBLIN ZONING REVIEW Completed CDRC TRANSMITTAL

TO: Development Services Department, Rezoning Section

FROM: Elisa Hamblin, AICP, Principal Planner

PROJECT: 6000 E Valencia Rd
Parcel: 140360120
Zoning: R-1/I-1
T19SE00017 (SE-19-17)
Zoning Examiner Special Exception Procedure

TRANSMITTAL: June 25, 2019

The proposed commercial use falls under UDC Article 4.8.7, Table 4.8-5: Permitted Uses - Industrial Zones. Commercial Land Use Group with Land Use Class/Type: Communications: Wireless Communication, subject to Use Specific Standards 4.9.13.Q and 4.9.4.I.2, .3, and .7

Vehicular Access: = Vehicular access appears to be adequate
Vehicle Parking Required = Not required
Vehicle Parking Provided = None provided
Short Term Bicycle Required = Not required
Short Term Bicycle Provided = None provided
Long Term Bicycle Required = Not required
Long Term Bicycle Provided = None provided
Off-Street Loading Required = Not required
Off-Street Loading Provided = Not required
Pedestrian Access: = Pedestrian access appears to be adequate
Allowed Building Height: = 75'
Proposed Building Height: = 100'

Should you have questions, please contact me at (520)837-4966 or elisa.hamblin@tucsonaz.gov.
06/27/2019 ZELIN CANCHOLA DOT TRAFFIC REVIEW Approved
06/27/2019 HEATHER THRALL SIGNS SIGN CODE REVIEW Completed project: T19SE00017
For: new cell tower
RE; signage review
Reviewer: H. Thrall
Date: 6/27/19

1) No billboards exist at this park (Pima County).

2) Signage should be limited to mounting on the walls of the enclosure. Any warning/safety signage should be limited in size to 12 square feet and less and non-illuminated. Signage may be reflective. No permits required.
07/02/2019 ANDREW CONNOR LANDSCAPE REVIEW Completed Landscape has no comments.
12/16/2019 LOREN MAKUS ENGINEERING REVIEW Completed