Permit Number: T19CM07637
Parcel: 13824083A

Review Status: Completed

Review Details: REVISION - - 2ND

Permit Number - T19CM07637
Review Name: REVISION - - 2ND
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/18/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Comment not resolved. Include the following information regarding the vents for the propane-fired unit heaters on the drawings: the distance from the exterior wall to the listed terminal cap, size and slope of the vent, the type of vent pipe (i.e. single-wall or double wall), any required thimbles, and how the vent will be supported. [Second comment: Comment not addressed.] [Initial comment: Provide details for the installation of the unit heater vents. The details are to include the required dimensions from the heater to the exterior wall, the distance from the exterior wall to the listed terminal cap, size and slope of the vent, the type of vent pipe (i.e. single-wall or double wall), any required thimbles, and how the vent will be supported. Reference: Section 501.14, IFGC 2018.]
08/26/2020 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. Previous Comment; Sheet A-4; Egress Plan: Per the IBC Section 1017.3, exit access travel distance shall be measured from the most remote point of each room or space along natural and unobstructed paths of horizontal and vertical (not diagonal) egress travel to an exit. Please revise this plan and indicate the maximum distance meets the requirements of the IBC Table 1017.2 (250' for F-1).
2. Previous Comment; Sheet A-4; Drinking Fountain: Per the IBC Section 1109.5.1, one drinking fountain shall comply with requirements for people in a wheelchair, and one drinking fountain shall comply with requirements for standing people. Use the 2009 ICC/ANSI Figure 602.5(b).
3. General: Please provide written responses to all review comments.

Final Status

Task End Date Reviewer's Name Type of Review Description
09/09/2020 KROBLES1 OUT TO CUSTOMER Completed