Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T19CM04184
Parcel: 11720029A

Address:
280 S CHURCH AV

Review Status: Completed

Review Details: RESUBMITTAL - TI ALL

Permit Number - T19CM04184
Review Name: RESUBMITTAL - TI ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/05/2019 ALEXANDRA HINES ZONING REVIEW Reqs Change RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Please resubmit updated drawings along with a detailed comment response letter, which states how all zoning review comments were addressed. This may be achieved in Bluebeam session.

Zoning has reviewed the building plans for compliance with the issued development package (DP19-0038) and found that the building plans are consistent with the issued development package as it relates to the zoning requirements, which includes the building square footage, building height, building footprint, and location on the site.

2. Comment not fully addressed: Remove landscape sheets. Removing is preferred since stamped sheets from each record can be slipped together on the job site. If not removing mark each sheet "FOR REFERENCE ONLY".

Zoning will review the building plans on the next submittal to assure that any updates made to the building plans or the development package does not affect zoning requirements. Zoning cannot approve the building plans until all PDSD commercial plans reviewers have also approved the building plans.

Alexandra Hines, AICP - Lead Planner
520-837-6975 - alexandra.hines@tucsonaz.gov
08/27/2019 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change T19CM04184

1) Detail 6 on sheet x2.0. The minimum clear height from the lowest sign to grade should be 84". Reference City of Tucson Technical Standards Manual (TSM) section 7-01.4.3
2) Sheet P2.7. Coordinate with Development Plan. Show on plans that any roof drains (downspouts) scupper underneath sidewalks or pedestrian walkways or are connected to the underground storm drain system as shown on sheet C4.0 of the Development Package. Reference TSM 7-01.4.1.E
3) As applicable since there is an underground drain system and sidewalk scuppers are proposed, remove the note on sheet P2.7 that says "ALL ROOF DRAINAGE ARE TO EXTEND DOWN THRU THE BUILDING AND SPILL TO GRADE. NO SITE STORM SYSTEM IS AVAILABLE FOR UNDERGOUND CONNECTION". Please note that roof drains used for emergency/secondary overflow can discharge directly to grade

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007
09/23/2019 PIMA COUNTY ELECTRICAL-COMMERCIAL REVIEW Completed
09/23/2019 PIMA COUNTY MECHANICAL-COMMERCIAL REVIEW Completed
09/23/2019 PIMA COUNTY BUILDING-COMMERCIAL REVIEW Completed
09/23/2019 PMARTIN1 WATER REVIEW Approved
09/23/2019 PIMA COUNTY PLUMBING-COMMERCIAL REVIEW Completed
09/24/2019 KROBLES1 FIRE REVIEW Reqs Change Move FDC to east side of stairs, so hose does not cross egress path.
Knox key boxes at Pump Room and at Fire Control Room. and room identification signs at these doors.
Deferred submittals for fire sprinkler, fire alarm and hood extinguishing system.
Other approved signage as required by IFC/IBC
Two way communication at elevators.
Emergency Responder Radio Coverage.
Automatic smoke detection system per IFC 907.5.
Standpipes to roof.
Address identification locations to be approved by TFD and PDSD.

Final Status

Task End Date Reviewer's Name Type of Review Description
09/25/2019 SBORZAK1 OUT TO CUSTOMER Completed