Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - TI ALL
Permit Number - T19CM04184
Review Name: RESUBMITTAL - TI ALL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/05/2019 | ALEXANDRA HINES | ZONING | REVIEW | Reqs Change | RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Please resubmit updated drawings along with a detailed comment response letter, which states how all zoning review comments were addressed. This may be achieved in Bluebeam session. Zoning has reviewed the building plans for compliance with the issued development package (DP19-0038) and found that the building plans are consistent with the issued development package as it relates to the zoning requirements, which includes the building square footage, building height, building footprint, and location on the site. 2. Comment not fully addressed: Remove landscape sheets. Removing is preferred since stamped sheets from each record can be slipped together on the job site. If not removing mark each sheet "FOR REFERENCE ONLY". Zoning will review the building plans on the next submittal to assure that any updates made to the building plans or the development package does not affect zoning requirements. Zoning cannot approve the building plans until all PDSD commercial plans reviewers have also approved the building plans. Alexandra Hines, AICP - Lead Planner 520-837-6975 - alexandra.hines@tucsonaz.gov |
08/27/2019 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | T19CM04184 1) Detail 6 on sheet x2.0. The minimum clear height from the lowest sign to grade should be 84". Reference City of Tucson Technical Standards Manual (TSM) section 7-01.4.3 2) Sheet P2.7. Coordinate with Development Plan. Show on plans that any roof drains (downspouts) scupper underneath sidewalks or pedestrian walkways or are connected to the underground storm drain system as shown on sheet C4.0 of the Development Package. Reference TSM 7-01.4.1.E 3) As applicable since there is an underground drain system and sidewalk scuppers are proposed, remove the note on sheet P2.7 that says "ALL ROOF DRAINAGE ARE TO EXTEND DOWN THRU THE BUILDING AND SPILL TO GRADE. NO SITE STORM SYSTEM IS AVAILABLE FOR UNDERGOUND CONNECTION". Please note that roof drains used for emergency/secondary overflow can discharge directly to grade John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov 520-837-5007 |
09/23/2019 | PIMA COUNTY | ELECTRICAL-COMMERCIAL | REVIEW | Completed | |
09/23/2019 | PIMA COUNTY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
09/23/2019 | PIMA COUNTY | BUILDING-COMMERCIAL | REVIEW | Completed | |
09/23/2019 | PMARTIN1 | WATER | REVIEW | Approved | |
09/23/2019 | PIMA COUNTY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
09/24/2019 | KROBLES1 | FIRE | REVIEW | Reqs Change | Move FDC to east side of stairs, so hose does not cross egress path. Knox key boxes at Pump Room and at Fire Control Room. and room identification signs at these doors. Deferred submittals for fire sprinkler, fire alarm and hood extinguishing system. Other approved signage as required by IFC/IBC Two way communication at elevators. Emergency Responder Radio Coverage. Automatic smoke detection system per IFC 907.5. Standpipes to roof. Address identification locations to be approved by TFD and PDSD. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
09/25/2019 | SBORZAK1 | OUT TO CUSTOMER | Completed |