Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T19CM03306
Parcel: 116193630

Address:
401 N BONITA AV

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T19CM03306
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/14/2019 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. Sheet G1.2 - Width of Exits ( Table 1005 ).Table 1005 does not exist , amend plan with the correct code information. IBC 107.2.1.
2. Sheet G1-2 - 1009.3 Exit access stairways - the section number is wrong , the comments listed are not from that section , with no interior stairs why is there a comment on enclosure of the stairs . Provide the correct code sections referenced and the correct code comments.IBC 107.2.1.
3. Sheet G1.2 - 1026 Exterior Exit Stairways and Ramps - 1026.2 Use in a means of Egress - the section numbers are wrong , amend the plan with the correct code sections. IBC 107.2.1.
4. Sheet G1.2 - Number of Exits ( Table 1015.1 ) table 1015.1 does not exist , comment listed is not from section 1015.1 . Amend the plan with the correct code information . IBC 107.2.1.
5. Sheet G1.2 - Minimum 2 Exits or Exit Access Doorways required > 49 occupants in any A-3 & B space . Minimum 2 Exits or Exit Access Doorways required when Common Path of Egress > 75 feet . Provide the correct sections and code comments referenced . IBC 107.2.1.
6. Sheet G1.2 - 3 Exits required when occupant load exceeds 500 . 4 Exits required when occupant load exceeds 1000 . Provide the code section referenced . IBC 107.2.1.
- Respond to plan review comments in writting.
- Cloud all corrections on plan .
05/14/2019 MARTIN BROWN FIRE REVIEW Reqs Change Indicate location of all panic door hardware
05/21/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
05/21/2019 ROBERT SHERRY WATER REVIEW Completed
05/21/2019 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change 1. The occupant load used to calculate the required ventilation is not necessarily the same as the occupant load used for calculating exiting requirements. The occupant load used for calculating the minimum required ventilation is to be based on Table 403.3.1.1, IMC 2018 or an approved engineering analysis of the specific occupancy type. Reference: Section 403.3.1.1, IMC 2018.
2. Verify that the VAV control system is capable of supplying the minimum outside airflow rate required by Section 403.3.1.1, IMC 2018 over the entire range of supply airflow rates. Reference: Section 403.3.1.4, IMC 2018.
3. Verify that the building HVAC systems serving the classrooms and dining hall are exempt from the requirement of providing demand control ventilation. Reference: Section C403.7.1, IECC 2018.
06/06/2019 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved