| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/25/2019 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 06/25/2019 | RMCCOY1 | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | Coordinate the Mechanical Compliance Certificate with the plans . IBC 107.2.1. |
| 06/25/2019 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the following electrical plan review comments. Also provide a written response. 1. Provide complete compliance with the Tucson/Pima County Outdoor Lighting Code for the exterior lighting. See section 104 for the plan submittal requirements. 2. The line diagram does not correlate with the panel schedules concerning the new panel 'C'. 3. Provide a receptacle and switched lighting outlet for the servicing of the FC unit installed in the ceiling space. NEC 210.63, 210.70. Ref; 2012 Tucson/Pima County Outdoor Lighting Code. 2018 IBC 107.2.1, 2017 NEC |
| 06/25/2019 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet T1.0; Code Analysis: The Building Use is listed as a chapel, with a B Classification. Per the IBC Section 303.4, a place of religious worship should have an Occupancy Classification of A-3. Please verify and revise as required. 2. Sheet T1.0; Code Analysis: The tenant area indicates 1200 SF, but it appears on Sheet A1.0 the only improvement is to a building of 336 SF with a new roof system with overhangs. Please verify. 3. Sheet T1.0; Code Analysis: Please include the plumbing fixture calculations on this sheet, and verify the requirements of the IBC Section 2902.3.3 are met. 4. General: Please provide written responses to all review comments. |
| 06/26/2019 | MRESS1 | ENGINEERING | REVIEW | Passed | |
| 06/26/2019 | MRESS1 | ZONING | REVIEW | Reqs Change | Provide an updated vehicle parking calculation based on development plan D04-0024 |
| 06/26/2019 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 08/01/2019 | AMARTIN1 | PLUMBING-COMMERCIAL | REVIEW | Needs Review | |
| 08/01/2019 | AMARTIN1 | WATER | REVIEW | Needs Review |