Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T18CM07663
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/27/2018 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 11/27/2018 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Revise the description of the envelope assemblies to correspond to those shown on the drawings (e.g. no continuous insulation is shown on the wall and roof sections). [Initial comment: Provide energy code compliance calculations for the addition to the building envelope; use the climate zone for Tucson. Provide sufficient detail on the drawings to evaluate the energy compliance of the additions to the building envelope. The information shall, as a minimum, include U-factors of the envelope systems and fenestration components, along with the R-values of the insulation and the SHGC for the fenestration. Reference: Sections C101.4.3, C101.5, C103.2, C303, and C401.2.1, International Energy Conservation Code 2012.] 2. Clarify the difference between the total cooling load capacity for HP-B as noted in the reply to the comments and the load calculations versus the scheduled cooling load capacity. [Initial comment: Coordinate the load calculations for HP-A and HP-B with the scheduled capacities. (Note that the load calculations for HP-A describe the unit as a split system rather than a packaged unit.) Reference: Section C403.2.2, IECC 2012.] |
| 11/27/2018 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 11/27/2018 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Comment not addressed. [Initial comment: Provide the dimensions of the new roof scupper. Reference: Sections 1106 and 1108.3, IPC 2012.] 2. Comment not addressed. [Initial comment: Provide secondary (overflow) roof drainage or provide structural calculations to show that the roof is capable of supporting the additional rain load. Reference: Sections 1106 and 1107.] |
| 11/28/2018 | AVAUGHN1 | ZONING | REVIEW | Needs Review |