Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T18CM07565
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/24/2018 | MCASTRO2 | ZONING | REVIEW | Approved | |
| 09/24/2018 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Provide heating/cooling load calculations for the new heat pumps. 2. Provide a 4" diameter exhaust vent for the clothes dryer. |
| 09/24/2018 | GPERU1 | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Provide certificate of compliance or electrical lighting calculations for verification in accordance with IECC C405.2 2. Specfify the amperage rating of the new electrical panel. |
| 09/24/2018 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Approved | |
| 09/24/2018 | GPERU1 | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. The water dispenser controls reqyured to be ADA compliant for operation at the sink. Please verify. |
| 09/24/2018 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 09/24/2018 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Verify the presence of a water pressure regulator (75-85 PSI). 2. Verify the valave handle on the water dispenser is listed as being accessible. 3. Provide 3" horizontal waste for clothes washer & sink. |
| 09/24/2018 | JVINCEN1 | FIRE | REVIEW | Approved | |
| 09/25/2018 | SVALENZ1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review |