Permit: T18CM07565
Permit Details
Status:
Expired
Type:
Commercial Building
Address:
2811 N FLOWING WELLS RD 105
Address NEW:
2811 N FLOWING WELLS RD 105
Apply Date:
09/24/2018
Applicant:
Description:
TI: OFFICE
Permit Reviews
Permit Number - T18CM07565
Permit Status: Expired
Permit Description: TI: OFFICE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/24/2018 | COMMERCIAL - TI | 09/25/2018 | COMPLETED |
| 09/25/2018 | COMMERCIAL - TI | 10/01/2018 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T18CM07565
Permit Status: Expired
Permit Description: TI: OFFICE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/24/2018 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T18CM07565
Permite Description: TI: OFFICE
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/21/2019 | COT - LCBU - Framing | N/A | Canceled | {Activity date: 08/21/2019; Status: Not Applicable; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } |
Completed Inspections
Permit Status: Expired
Permit Number: T18CM07565
Permit Description: TI: OFFICE
Total Completed Inspections - 14
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/21/2018 | COT - LCBU - Building Above Ceiling | Passed | {Activity date: 12/21/2018; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - } | |
| 12/21/2018 | COT - LCEL - Electrical Intermediate | Passed | {Activity date: 12/21/2018; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - } | |
| 12/21/2018 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 12/21/2018; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - } | |
| 12/21/2018 | COT - LCPL - Rough Soil | Passed | {Activity date: 12/21/2018; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - } | |
| 12/21/2018 | COT - LCEL - Electrical Above Ceiling | Passed | {Activity date: 12/21/2018; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - } | |
| 12/21/2018 | COT - LCBU - Building Progress | Passed | {Activity date: 12/21/2018; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - } | |
| 01/03/2019 | COT - LCME - Mechanical Intermediate | Passed | {Activity date: 01/03/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - } | |
| 01/15/2019 | COT - LCME - Mechanical Above Ceiling | Passed | {Activity date: 01/15/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - } ; {Activity date: 01/03/2019; Status: Partial Approval; Inspector: TVALENCIA; Comment: Entered by CBELL1 - 1- Supply and Return flex duct is okay for ceiling grid.} | |
| 02/08/2019 | COT - LCEL - Electrical Final | Passed | {Activity date: 02/08/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - } | |
| 02/11/2019 | COT - LCME - Mechanical Final | Passed | {Activity date: 02/11/2019; Status: Approved; Inspector: RSHERRY; Comment: Entered by RSHERRY1 - REVIEW OF AIR BALANCE REPORT COMPLETED} ; {Activity date: 02/08/2019; Status: Partial Approval; Inspector: TVALENCIA; Comment: Entered by CBELL1 - } ; {Activity date: 09/27/2018; Status: Prior to Final Inspectn; Inspector: RSHERRY; Comment: Entered by RSHERRY1 - AIR BALANCE REPORT REQUIRED} | |
| 02/11/2019 | COT - LCPL - Plumbing Final | Passed | {Activity date: 02/11/2019; Status: Approved; Inspector: RSHERRY; Comment: Entered by RSHERRY1 - REVIEW OF WATER CHLORINATION REPORT COMPLETED.} ; {Activity date: 02/08/2019; Status: Partial Approval; Inspector: TVALENCIA; Comment: Entered by CBELL1 - } ; {Activity date: 09/25/2018; Status: Prior to Final Inspectn; Inspector: RSHERRY; Comment: Entered by RSHERRY1 - WATER CHLORINATION REPORT REQUIRED} | |
| 03/15/2019 | COT - FCON - Fire - Final | Passed | {Activity date: 03/15/2019; Status: Approved; Inspector: CBASALDUA; Comment: Entered by CBASALD1 - } ; {Activity date: 02/08/2019; Status: Denied; Inspector: jvincent; Comment: Entered by JVINCEN1 - 1. repair sprinkler heads. some are bent. some are too low below the tiles or too high. 2. provide key for knox box. 3. annual and 5yr inspection report for fire alarm. 4. annual inspection report for fire alarm. 5. AES radio was not permitted. replace with cellular dialer and phone line. 6. power strip set up next to fire alarm panel for transformer needs to be corrected and locked. 7. suite number rear doors. 8. flush FDC's, AHJ to witness. 9. add supports to arm overs that were added. 10. knox FDC plugs needed after flush. Have on site during flush so we can install immediatley after flush. 11. mount extinguishers. Contact: Jay Post 310-1611} |
|
| 08/21/2019 | COT - LCBU - Building Final | Passed | {Activity date: 08/21/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - Note: the address on the permit was the contractors address. The site address is 3700 n 1st ave. # 2021} ; {Activity date: 02/08/2019; Status: Partial Approval; Inspector: TVALENCIA; Comment: Entered by CBELL1 - 1- Bldg. final is okay for C of O pending Fire inspection,air balance and water chlorination report approval} | |
| 08/21/2019 | ENGR Engineering Final | Passed | {Activity date: 08/21/2019; Status: Approved; Inspector: BBENEDON; Comment: Entered by DMERANZ1 - This inspection is actually 3700 N. 1st Ave., Apt. 2021.} |