Permit Number: T18CM06259
Parcel: 140200220

Address:
841 E BANTAM RD

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T18CM06259
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/06/2021 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. General: The structural calculations were not included in this submittal. Please provide.
10/13/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
10/13/2021 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Completed
10/21/2021 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change Please address the floowing electrical review comments. Also provide a written response.
#1. Per the previous review comment #3, and response from EDG West. Plan sheet E.5 is still not clear concerning the feed to WH #1. The line diagram still shows 2# 1/0 conductors and 3 sets of 3#8's in a 1-1/4" conduit and connected to 1 40 amp OCPD. Also the EGC is not sized correctly, see NEC 250.122. Plan sheet E.4 shows WH#1 on ckts 5-7, 9-11, where is 10-12? Please clarify.
Comment #4 and response. #2. Please address and verify that the use of Non Metalic Sheathed Cable will not be allowed to remain in use for the existing branch circuits shown on plan sheet E.2.
Ref; 2018 IBC 107.2.1, 2017 NEC.
10/22/2021 SSHIELD1 ENGINEERING REVIEW Reqs Change See Zoning comments
10/22/2021 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T18CM06259
841 E Bantam Rd
Building Expansion & Interior Remodel

TRANSMITTAL: October 22, 2021
This site is located in the R-2 zone (UDC 4.7.9). Religious Use is an allowed use in the zone.

1. Zoning acknowledges that DP17-0239 was submitted for this site. 1st review back in August of 2018 and returned for correction in September of 2018. Per UDC Article 3.3.3.G.5.c, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. That said DP17-0239 has expired and requires a new application and submittal. Until the new has been submitted and approved Zoning cannot approve the building plans.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.