Permit: T18CM06259
Permit Details
Apply Date:
08/10/2018
Applicant:
Frank Rendon
Description:
T17DV02372 CHANGE OF USE RESIDENTIAL TO CHURCH T15CM04261 WITHDRAWN T17CM07421
Permit Reviews
Permit Number - T18CM06259
Permit Status: Inspections
Permit Description: T17DV02372 CHANGE OF USE RESIDENTIAL TO CHURCH T15CM04261 WITHDRAWN T17CM07421
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/10/2018 | PLANS OK TO SUBMIT - COMM | 08/27/2018 | COMPLETED |
| 08/27/2018 | COMMERCIAL - NEW | 10/09/2018 | COMPLETED |
| 09/30/2021 | RESUBMITTAL | 10/22/2021 | COMPLETED |
| 11/16/2021 | RESUBMITTAL | 01/31/2022 | COMPLETED |
| 11/25/2019 | RESUBMITTAL | 01/08/2020 | COMPLETED |
| 11/08/2023 | COMMERCIAL REVIEW - FULL v.1 | 11/08/2023 | REQUIRES RESUBMIT |
| 11/08/2023 | COMMERCIAL REVIEW - FULL v.2 | 11/13/2023 | IN REVIEW |
| 11/13/2023 | COMMERCIAL REVIEW - FULL v.3 | 11/14/2023 | APPROVED |
| 11/14/2023 | RESTAMP - COMMERCIAL v.1 | 11/15/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - T18CM06259
Permit Status: Inspections
Permit Description: T17DV02372 CHANGE OF USE RESIDENTIAL TO CHURCH T15CM04261 WITHDRAWN T17CM07421
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 08/10/2018 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 11/14/2023 | AIR BALANCING REPORT IS REQUIRED. |
| 11/14/2023 | WATER STERILIZATION REPORT IS REQUIRED. |
Conditions
Permit Number - T18CM06259
Permit Status: Inspections
Permit Description: T17DV02372 CHANGE OF USE RESIDENTIAL TO CHURCH T15CM04261 WITHDRAWN T17CM07421
| Date | Description | Comments |
|---|---|---|
| 11/15/2023 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: T18CM06259
Permite Description: T17DV02372 CHANGE OF USE RESIDENTIAL TO CHURCH T15CM04261 WITHDRAWN T17CM07421
Total Outstanding Inspections - 10
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/13/2021 | COT - LCME - Mechanical Final | N/A | Re-inspection required | {Activity date: 10/13/2021; Status: Prior to Final Inspectn; Inspector: RSHERRY; Comment: Entered by RSHERRY1 - AIR BALANCE REPORT REQUIRED} |
| 10/13/2021 | COT - LCPL - Plumbing Final | N/A | Re-inspection required | {Activity date: 10/13/2021; Status: Prior to Final Inspectn; Inspector: RSHERRY; Comment: Entered by RSHERRY1 - WATER DISINFECTION REPORT REQUIRED} |
| 02/12/2024 | COT - HCBU - Preslab | N/A | Re-inspection required | 2/6/24: Preslab not ready 2/12/24: Called Carlos once arrived on site for access code and did not get an answer. Gate is locked no access to site. 2/12/24: detail 3/S1 calls out for dowels every 48" O.C with 8" embedment into new footings and existing footing, missing throughout, rebar supports are creating voids as reinforcements (large debris supporting rebar), footing F4 requires 24"x24" by 18" height. |
| 12/01/2023 | COT - LCPL - Rough Soil | N/A | Partial Pass | 12/1/23: partial plumbing underground for rooms 102,105,106,107,108 and mop sink at north east side of building and restroom, pending tie into existing bathrooms. Ok to backfill progress areas. Shading required. |
| 01/13/2025 | COT - LCEL - Electrical Above Ceiling | N/A | Not Ready | 1/13/25: not ready wanted electrical clearance |
| 01/13/2025 | COT - LCEL - Electrical Final | N/A | Not Ready | 1/13/25: not ready wanted electrical clearance |
| 01/13/2025 | COT - LCEL - Electrical Progress | N/A | Not Ready | 1/13/25: not ready wanted electrical clearance |
| 06/17/2025 | COT - LCEL - Grounding/Bonding | N/A | Re-inspection required | 6-17-25: missing knockout at panel located on west side, label all breakers on both panels, outdoor receptacle near subpanel must be weather resistant and requires a bubble cover, missing smoke detector in kids room. |
| 01/13/2025 | COT - LCEL - Outdoor Lighting | N/A | Not Ready | 1/13/25: not ready wanted electrical clearance |
| 06/17/2025 | COT - LCPL - Sewer | N/A | Not Ready | 6-17-25: not ready. |
Completed Inspections
Permit Status: Inspections
Permit Number: T18CM06259
Permit Description: T17DV02372 CHANGE OF USE RESIDENTIAL TO CHURCH T15CM04261 WITHDRAWN T17CM07421
Total Completed Inspections - 9
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/15/2024 | COT - HCBU - Preslab | Passed | ||
| 04/11/2024 | COT - HCBU - Framing | Passed | ||
| 04/22/2024 | COT - LCEL - Electrical Intermediate | Passed | 4/22/24: intermediates passed | |
| 06/14/2024 | COT - LCPL - Rough Soil | Passed | 12/1/23: partial plumbing underground for rooms 102,105,106,107,108 and mop sink at north east side of building and restroom, pending tie into existing bathrooms. Ok to backfill progress areas. Shading required. 6/14/24: Main water line per plans ok to proceed. Shading required |
|
| 07/26/2024 | COT - BULD - SWG Clearance | Passed | 7/26/24: SWG CLEARANCE | |
| 01/13/2025 | BULD - Electrical Clearance | Passed | 01/13/25 TEP Clearance code; INCR pending cut over schedule. |
|
| 06/17/2025 | COT - LCEL - Electrical Above Ceiling | Passed | 6-17-25:approved | |
| 06/17/2025 | COT - LCEL - Electrical Underground | Passed | 6-17-25:approved | |
| 06/17/2025 | COT - LCEL - Outdoor Lighting | Passed | 6-17-25:approved |