Permit Number: T18CM05839
Parcel: 12507534A

Address:
2246 E 7TH ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T18CM05839
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/31/2019 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Needs Review
06/20/2019 ELISA HAMBLIN ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL


FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: T18CM05839, 2246 E 7th St
Detached garage and home remodel

TRANSMITTAL: June 3, 2019

COMMENTS: The following comments are for the purpose of applying for a variance before the Board of Adjustment (UDC Section 3.10.1).

This site is located in the R-1 zone (UDC 4.7.9). Single-family residential is a permitted use in this zone (Table 4.8-2). See Use Specific Standards 4.9.7.B.6, .9 & .10.

The applicant is proposing to construct an approximately 468 square foot detached garage in the rear of the property and construct an addition to an existing home.

Related to the garage:
The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The minimum setback to the south property line is 7' based on a wall height of 10'6". The proposal is for a 1'6" setback.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The minimum setback to the west property line is 6'10" based on a wall height of 10'2.5". The proposal is for a 6'0" setback.

The minimum setback to a side street property line is ten (10) feet (UDC Section 6.4.5.C.1.b). The applicant is proposing a 6'0" side street (east) setback.

Related to the home addition:
The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The minimum setback to the west property line is 8'3" based on a wall height of 12'4". The proposal is for a 6'5.5" setback.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The minimum setback to the west property line is 8'5" based on a wall height of 13'. The proposal is for an 8' setback.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/20/2020 PC_TGUTHEI1 APPROVAL SHELF Completed
07/20/2020 PC_TGUTHEI1 OUT TO CUSTOMER Completed
07/20/2020 PC_TGUTHEI1 REJECT SHELF Completed