Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - NEW
Permit Number - T18CM04433
Review Name: COMMERCIAL - NEW
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/11/2018 | MARTIN BROWN | FIRE | REVIEW | Approved | |
06/21/2018 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Provide a site drawing showing the location of the proposed gravity grease interceptor, the size, route, and slope of the building sewer, the location of all cleanouts in the building sewer, and the location of the connection of the building sewer to the public sewer. Reference: Section 107.2.1, IBC 2012. 2. Appliances (e.g. espresso machines, ice makers, etc.) to be directly connected to the water supply system that do not have listed, integral backflow preventers or integral air gaps conforming to Section 608.13.1, IPC 2012 require backflow prevention. Specify the type of backflow prevention device required for each water connection. Reference: Sections 608.1 and 608.3, IPC 2012. 3. Provide the rim elevation of the next upstream sanitary manhole and the first floor elevation. Determine the need for a backwater valve per Section 715.1, IPC 2012, as amended by the City of Tucson. |
06/21/2018 | ROBERT SHERRY | WATER | REVIEW | Reqs Change | Show the location of the proposed water meter, backflow preventer, and the water service pipe on a site plan. The development package is not a substitute for a complete site plan. Reference: Section 107.2.5, IBC 2012. |
06/22/2018 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Provide calculations for the building envelope to demonstrate compliance with the energy code; use the climate zone for Tucson. Provide sufficient detail on the drawings to evaluate the energy compliance of the building envelope. As a minimum, the information shall include U-factors of the envelope systems and fenestration components, along with the R-values of the insulation and the SHGC for the fenestration. Reference: Sections C103.2 and C401.2, International Energy Conservation Code 2012. 2. Provide heating and cooling load calculations, using the exterior design conditions shown in Section 302.2, IECC 2012, as modified by the City of Tucson. 3. Verify that the installer setup menu for the specified programmable thermostat includes off-hour and set-back control, automatic shutdown and automatic start-up control (i.e. the thermostat is capable of automatically adjusting the start time of the HVAC equipment in order to bring the interior conditions to the desired temperature at the start of occupancy) and, if the thermostat does not require manual changeover from the heating and cooling modes, it restricts set point overlap. Reference: Section C403.2.4, IECC 2012. |
06/26/2018 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet A0.0; Project Data: For the occupancy type, please add a note indicating 'per the IBC Section 303.1.1, a building used for assembly purposes with an occupant load of less than 50 persons shall be classified as a Group B occupancy. 2. Sheet A0.0; Reference Codes: Please add the 2009 ICC/ANSI A117.1 Accessibility Code to this sheet. 3. Sheet A2.1; Floor Plan: Please add a note to the plan stating the requirements of the IBC Section 1104.2 indicate at least one accessible route to connect accessible buildings and accessible facilities are met (route to the entrance and to the restroom). 4. Sheet A2.1; Floor Plan: Per the IBC Section 1004.5, the total occupant load for this facility will be 34 (4 in the building and 30 in the outdoor seating area). Per the IBC Table 2902.1 and Section 2902.2, since the occupant load is greater than 15, two separate restroom facilities will be required. The plan only indicates one restroom. Please verify. 5. Sheet A2.1; Floor Plan: The enlarged restroom plan references 9/A2.5 on this sheet. Please revise the reference to 5/A2.5. 6. Sheet A2.1; Floor Plan: Please cut Section 10/A4.5 on the building plan. 7. Sheet A2.4; Keynotes: Note 9 references Detail 10/A6.2 for a parapet wall opening. Please revise the reference. 8. Sheet A2.4; Keynotes: Note 12 references Detail 11/A6.1 for a vent through the roof. Please revise the reference. 9. Sheet A4.1; Keynotes: Note 12 references Detail 10/A6.2 for a parapet wall opening. Please revise the reference. 10. Sheet A4.2; Sections 2 and 3: The top of the wall indicates Detail 2/A6.2. Please revise the detail. 11. Sheet A4.2; Sections 2 and 3: The wall indicates a Detail 10/A6.2 sim. Please revise the detail. 12. Sheet A4.3; Section 4: A detail is indicated at the top of the wainscoat. Please finish the detail. 13. Sheet A6.1; Section 1: The details indicate 2 and 3/A6.2. Please revise the details. 14. General Structural Notes: The City of Tucson requires all lettering to be a minimum of 3/32" in height. Please revise. 15. General Structural Notes; Foundation: Please provide one copy of the soil report for review. 16. Sheets S2, S3, and S4; Plans: Please provide a north arrow on the plans. 17. Sheet S4; Framing Plan: Along Grid 4, a beam SB2 is noted. There is no SB2 beam indicated in a schedule. Please verify. 18. Structural Calculations (Sheet W3); Sheet S4 (Column Schedule): Please indicate the various column numbers on the foundation key plan (W3) to match the columns indicated in the calculations (Sheet W1). 19. Structural Calculations; Sheet W2: Please relate the footings in the calculations on Sheet W2 to the footings indicated on Sheet S2. 20. General: Please provide a site plan with this submittal. 21. General: Please provide written responses to all review comments. |
07/05/2018 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Steve Shields Site Section Manager PROJECT: 9330 E. Golf Links Road T18CM04433 Building Plan (1st Review) TRANSMITTAL DATE: July 5, 2018 1. The building plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed. 2. The building plans have been reviewed for compliance with DP18-0056. Although the building plans appear to comply with the requirements shown on DP18-0056 Zoning cannot approve the building plans until all other review agencies, included 3rd party review, have approved. Once the above comments are addressed Zoning will provide an over-the-counter review. Please call or email to schedule an appointment for this review. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
07/06/2018 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the following electrical plan review comments. Also provide a written response. #1. Revise the specification for luminaires 'SF' and 'SC' the lamp color temperature cannot exceed 3500K per section 402.1, Outdoor lighting Code. The cut sheets show them rated at 4000K. |
07/10/2018 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | T18CM04433 1) Sheet P1.3; As shown, two roof drains discharge onto walkways, the southern roof drain and northern drain. Show these roof drains to scupper underneath the walkways. Reference City of Tucson Technical Standards Manual section 7-01.4.1.E. Suggest referencing an applicable Pima Association of Governments (PAG) standard detail (204-205.5) found in the following link. http://apps.pagnet.org/standardspecifications/ 2) Engineering can conduct an over the counter review once the above comment and other department comments have been addressed. John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov 520-837-5007 |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
07/30/2018 | AVAUGHN1 | OUT TO CUSTOMER | Completed |
07/30/2018 | AVAUGHN1 | REJECT SHELF | Completed |