Permit Number: T18BU00593
Parcel: 11504498B

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T18BU00593
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/14/2018 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. The structural calculations for the pool constrruction indicate an in-ground installation into earth. Provide pool structural calculations that are site specific and detail the roof-top installation.
2. Provide plans and details for the engineered pool vault as specified in the CONCRETE AND REBAR NOTES section.
3. Show the secondary leakage containment and disposal system on the plans as called out on note #13 in the CONCRETE AND REBAR NOTES section.

Please provide written responses to plan review comments.
12/21/2018 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed

Final Status

Task End Date Reviewer's Name Type of Review Description
12/27/2018 AVAUGHN1 APPROVAL SHELF Completed
12/27/2018 AVAUGHN1 OUT TO CUSTOMER Completed
12/27/2018 AVAUGHN1 REJECT SHELF Completed