Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T17CM03846
Parcel: 141186030

Review Status: Completed

Review Details: COMMERCIAL - NEW

Permit Number - T17CM03846
Review Name: COMMERCIAL - NEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/17/2017 MARTIN BROWN FIRE REVIEW Approved
05/25/2017 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Needs Review Provide plans sealed by an Arizona Registrant that show in detail that the plumbing design will comply with the requirements of the 2012 International Plumbing Code as amended by the City of Tucson. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304 and Section 107.2.1, IBC 2012.
05/25/2017 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change Provide plans sealed by an Arizona Registrant that show in detail that the Electrical design will comply with the requirements of the 2011 NEC as amended by the City of Tucson. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304 and Section 107.2.1, IBC 2012.
05/25/2017 ROBERT SHERRY WATER REVIEW Completed
05/25/2017 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Needs Review Provide plans sealed by an Arizona Registrant that show in detail that the mechanical design will comply with the requirements of the 2012 International Mechanical Code as amended by the City of Tucson. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304 and Section 107.2.1, IBC 2012.
05/30/2017 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Principle Planner

PROJECT: Hughes Federal Credit Union
T17CM03846
Building Plan (1st Review)

TRANSMITTAL DATE: May 30, 2017

1. The building plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

2. The development package sheets provided within the building plan set either need to be the signed approved sheets, removed from the building plan set or marked as for reference only.

3. Sheet AS-101 the short term bicycle parking details do not match what is shown on the development package.

4. Until the above comments have been addressed and all other PDSD review agencies have approved the building plans zoning cannot approve.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
06/01/2017 LOREN MAKUS ENGINEERING REVIEW Approved
06/13/2017 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. Sheet G-101; Code and Data Summary: Reference is made to the 2009 International Energy Conservation Code. Please revise to the 2012 edition. The energy code review, including the building envelope, will be performed in the mechanical review.
2. Sheet G-101; Code and Data Summary (Height and Area Limitations): Per the IBC Section 506.3, the allowable square footage per floor is (3 x 23,000) + 23,000 = 92,000 square feet using the automatic sprinkler system increase. Please revise the drawing.
3. Sheet G-101; Code and Data Summary (Plumbing Fixture Count): Per the IBC Section 2902.1.1 and Table 2902.1, the number of male occupants is 30 (or 29) and the number of female occupants is 29 (or 30). The table requires one water closet per 25 occupants for each sex for the first 50, therefore 30/25 = 1.2 male (round up to 2) and 29/25 = 1.16 female (round up to 2). Therefore, two water closets for each sex (four total) are required. Please revise the calculation and the drawings.
4. Sheet G-101 (Code Plan); Sheet A-101 (Floor Plan): The code plan indicates an exit door in the northwest area of the exterior wall. The floor plan indicates door 106A at the corridor leading to the exit door location. The door schedule on Sheet A-600 indicates a card reader is required at this door. Per the IBC Section 1014.2, an exit access shall not pass through a room that can be locked. Please verify and revise the drawing.
5. Sheet G-101; Code and Data Summary (Occupant Load): The IBC Table 1004.1.2 indicates 100 square feet per occupant gross. The occupant load of 59 is determined from the 5923 usable square feet. Please revise the occupant load based on the 6262 gross square feet.
6. Sheet S002; Design Data: Reference is made to the 2012 International Existing Building Code as being applicable to this project. All submitted plans are for new construction only. Please remove reference to that code.
7. Sheet S002: Please provide a special inspection certificate reflecting all required special inspections as outlined in the Special Inspection Schedule.
8. Sheet S100 (Foundation Plan); Sheet S400 (Details 4 and 6): In several locations on the plan, Details 4/S400 and 6/S400 are indicated. These two details reference Detail 1/S412. That sheet is not included in this submittal. Please revise.
9. Sheet S100A (Foundation Plan); Sheet S400 (Detail 4): On Grid 1 east of Grid C on the plan, Detail 4/S400 is indicated. This detail references Detail 1/S412. That sheet is not included in this submittal. Please revise.
10. Sheet S200 (Framing Plan); Structural Calculations: The calculations indicate beams 11 and 13 require a W16x26, while the plan indicates a W14x26 (Grid D between Grids 1 and 3 and Grid D between Grids 6 and 7). Please clarify.
11. Sheet S200 (Framing Plan); Sheet S301 (Detail 5): On Sheet S200, a Detail 5/S301 is cut on Grid 1 between Grids C and D. The detail is cut at a solid wall, while Detail 5 indicates a lintel over an opening. Please revise.
12. Sheet S200 (Framing Plan); Sheet S300 (Detail 1): On Sheet S200, a Detail 1/S300 is cut on Grid 8 between Grids B and G. The detail is cut at a solid wall, while Detail 1 indicates a lintel over an opening. Please revise.
13. Sheet S400 (Detail 5); Sheet A-302 (Section 3): These sections are cut at the same location on the plan. Please revise the Detail 5/S400 to match Section 3/A-302.
14. Sheet S400; Detail 5: Please indicate the minimum concrete cover required at the face of the steel column.
15. Sheet S421; Detail 1: This detail indicates Detail 1/S420. That detail references Detail 1/S412 That sheet is not included in this submittal. Please revise.
16. Sheet A-101: The minimum number of required plumbing fixtures shall be accessible to the building occupants per the IBC Sections 2902.2 and 2902.3.1. Door 106A (see the door schedule on Sheet A-600) restricts access to two restrooms. Please revise the plan.
17. Sheet A-111 (Reflected Ceiling Plan); Sheet E-301 (Lighting Plan): Please provide a note on Sheet A-111 to reference Sheet E-301 for the exit lighting.
18. Sheet A-111 (Reflected Ceiling Plan); Sheet E-301 (Lighting Plan): Per the IBC Section 1011.1, directional exit signage may be required. Please verify the requirements of that Section are met.
19. Sheet A-111A; Reflected Ceiling General Notes (Note 2): Please add in the note to reference Sheet A-201 in addition to Sheet A-200.
20. Sheet A-111A; Details 2, 3, and 4: Where metal stud framing and bracing are indicated in the details, please include the metal stud size and gauge. In addition, indicate the connector sizes and quantities for the metal studs to the various structural members.
21. Sheets A-120 and A-121; Finish Plan Notes (Note 1): The note references page A-123. Please revise.
22. Sheet A-122; General Notes (Note 1): The note references the 2009 IBC. Please revise.
23. Sheet A-400; Elevation 2: Please indicate the location of the horizontal grab bar on the back wall per the ICC/ANSI Figure 604.5.2.
24. Sheet A-401; Detail 11: A detail is cut at the top of this detail that references 5/A601. Please revise that reference.
25. General: The registrant's seal on the submittal drawings must include the expiration date of that license per the Arizona State Board of Technical Registration Rule R4-304. Please provide.
26. General; Sheet G-100 (Note): Please remove the note concerning future submittals of the mechanical, electrical, fire protection, and plumbing design drawings and calculations. These must be included in this submittal, sealed by a licensed professional, and may not be deferred as 'design build' to a future time.
27. General: Please provide written responses to all review comments.
06/13/2017 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Approved
06/21/2017 GERRY KOZIOL WWM REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
07/27/2017 KROBLES1 OUT TO CUSTOMER Completed