Permit Number: T17CM02528
Parcel: 136129480

Review Status: Completed

Review Details: RESUBMITTAL - TI ALL

Permit Number - T17CM02528
Review Name: RESUBMITTAL - TI ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/17/2017 PIMA COUNTY BUILDING-COMMERCIAL REVIEW Reqs Change T17CM02528 –PLAN REVIEW COMMENTS – 2nd REVIEW
Reviewer: Chris Anderson, May 16, 2017

BUILDING – COMMERCIAL
Regarding response to previous Building comment 1, the resubmitted COMcheck is not different from the initial submittal. The storefront is still shown as thermally broken.
Regarding response to previous Building comment 5, the text of 1/A-1.1 must be minimum 3/32” high (upper and lower cases) to comply with City of Tucson commercial submittal requirements and not the text of braille. This has to do with legibility of the construction documents after printing and copying to digital form. Height of braille characters must be minimum 5/8-inches plus or minus 1/8” to comply with Table 703.2.4 of the ICC/ANSI A117.1-2009. Ref. ANSI A117.1 703.2.4.
05/17/2017 PIMA COUNTY MECHANICAL-COMMERCIAL REVIEW Approved
05/17/2017 PIMA COUNTY ELECTRICAL-COMMERCIAL REVIEW Reqs Change ELECTRICAL – COMMERCIAL
Regarding response to previous Electrical comment 1, either revise the outdoor lighting calculation to add 1 type “D” exterior fixture as a revision to T17CM00782 or delete 1 type “D” fixture from the building lighting plan for this permit.
Regarding response to previous Electrical comment 2, no revised interior lighting COMcheck was provided. Previous COMcheck indicates 3,083 SF of lighting area.
05/17/2017 PIMA COUNTY PLUMBING-COMMERCIAL REVIEW Approved
05/22/2017 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Principle Planner

PROJECT: AutoZone - 10210 E. Golf Links Road
T17CM02528
Building Plan (2nd Review)

TRANSMITTAL DATE: May 22, 2017

1. The building plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

2. It appears that the building plans match the proposed development package DP17-0032 but until the development package has been approved Zoning cannot approve the foundation plan.

3. Until the above comments have been addressed and all other PDSD review agencies have approved the building plans zoning cannot approve.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956