Review Date Reviewer's Name Type of Review Description Status Comments
05/04/2016 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Passed Preliminary drawings - not for construction
05/04/2016 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Passed Preliminary drawings - not for construction
05/04/2016 ROBERT SHERRY WATER REVIEW Passed Preliminary drawings - not for construction
05/05/2016 KEN BROUILLETTE FIRE REVIEW Reqs Change Waiting for exiting issue to be addressed
05/12/2016 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. SHEET S102: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. PLEASE REVISE THE SPECIAL INSPECTIONS.
2. SHEET S202; FLOOR FRAMING PLAN: THE DETAIL 260 CUT IN THE SOUTHWEST CORNER MECHANICAL AREA (SHOWN ON SHEET S504) INDICATES A SLAB ON GRADE, WHILE THE PLAN INDICATES STEEL FRAMING. PLEASE CLARIFY.
3. SHEET S207; FRAMING PLAN KEYNOTES: THERE ARE NO NOTES LISTED, BUT A KEY NOTE 4 IS INDICATED ON GRID 10.2 BETWEEN GRIDS C AND D. PLEASE CLARIFY.
4. SHEET S208; FRAMING PLAN 01; AT THE WEST WALL OF THE POOL, A DETAIL REFERENCES 'D TYP'. PLEASE CLARIFY.
5. SHEET S210; FRAMING PLAN KEYNOTES: THERE IS ONE NOTE LISTED, BUT KEYNOTES 1 AND 2 ARE INDICATED ON PLAN 04. PLEASE CLARIFY.
6. SHEET S301; SHEARWALL 7 (SW7): THIS SHEET INDICATES THE WALL EXTENDS PAST THE 12TH FLOOR TO THE ROOF, WHILE SHEET S209 AND SECTION 222 INDICATE THE SW7 STOPS AT THE 12TH FLOOR. PLEASE CLARIFY.
7. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
05/16/2016 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Passed
05/17/2016 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Maingate Hilton Superstructure
T16CM02856
Building Plan (1st Review)

TRANSMITTAL DATE: March 7, 2016

1. The building plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

2. Until all other PDSD review agencies have approved the building plans zoning cannot approve.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
05/17/2016 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
05/23/2016 LOREN MAKUS ENGINEERING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
02/08/2019 KROBLES1 OUT TO CUSTOMER Completed