Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - NEW
Permit Number - T16CM02856
Review Name: COMMERCIAL - NEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/04/2016 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | Preliminary drawings - not for construction |
| 05/04/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | Preliminary drawings - not for construction |
| 05/04/2016 | ROBERT SHERRY | WATER | REVIEW | Passed | Preliminary drawings - not for construction |
| 05/05/2016 | KEN BROUILLETTE | FIRE | REVIEW | Reqs Change | Waiting for exiting issue to be addressed |
| 05/12/2016 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. SHEET S102: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. PLEASE REVISE THE SPECIAL INSPECTIONS. 2. SHEET S202; FLOOR FRAMING PLAN: THE DETAIL 260 CUT IN THE SOUTHWEST CORNER MECHANICAL AREA (SHOWN ON SHEET S504) INDICATES A SLAB ON GRADE, WHILE THE PLAN INDICATES STEEL FRAMING. PLEASE CLARIFY. 3. SHEET S207; FRAMING PLAN KEYNOTES: THERE ARE NO NOTES LISTED, BUT A KEY NOTE 4 IS INDICATED ON GRID 10.2 BETWEEN GRIDS C AND D. PLEASE CLARIFY. 4. SHEET S208; FRAMING PLAN 01; AT THE WEST WALL OF THE POOL, A DETAIL REFERENCES 'D TYP'. PLEASE CLARIFY. 5. SHEET S210; FRAMING PLAN KEYNOTES: THERE IS ONE NOTE LISTED, BUT KEYNOTES 1 AND 2 ARE INDICATED ON PLAN 04. PLEASE CLARIFY. 6. SHEET S301; SHEARWALL 7 (SW7): THIS SHEET INDICATES THE WALL EXTENDS PAST THE 12TH FLOOR TO THE ROOF, WHILE SHEET S209 AND SECTION 222 INDICATE THE SW7 STOPS AT THE 12TH FLOOR. PLEASE CLARIFY. 7. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
| 05/16/2016 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Passed | |
| 05/17/2016 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Maingate Hilton Superstructure T16CM02856 Building Plan (1st Review) TRANSMITTAL DATE: March 7, 2016 1. The building plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed. 2. Until all other PDSD review agencies have approved the building plans zoning cannot approve. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
| 05/17/2016 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 05/23/2016 | LOREN MAKUS | ENGINEERING | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/08/2019 | KROBLES1 | OUT TO CUSTOMER | Completed |