Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - NEW
Permit Number - T16CM02493
Review Name: COMMERCIAL - NEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/07/2016 | KEN BROUILLETTE | FIRE | REVIEW | Passed | |
| 04/19/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
| 04/19/2016 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 04/19/2016 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 04/25/2016 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Steve Shields Principle Planner PROJECT: Banner University Medical Center - North Campus Parking Structure T16CM02493 Building Plan (1st Review) TRANSMITTAL DATE: April 25, 2016 1. The steel and stairs package has been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed. 2. The steel and stairs package has been reviewed and it appears that the plans match development package DP16-0030. But until development package DP16-0030 is approved Zoning cannot approve the steel and stairs package. 3. Until the above comments have been addressed and all other PDSD review agencies have approved the building plans zoning cannot approve. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
| 04/27/2016 | LOREN MAKUS | ENGINEERING | REVIEW | Needs Review | Development Package must be approved first. |
| 05/02/2016 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. SHEET G2.1.1; PROJECT CODE SUMMARY: THE REQUIREMENTS FOR THE OPEN PARKING GARAGE AS LISTED IN THE IBC SECTION 406.5, THE MINIMUM FIRE RESISTANCE RATINGS AS LISTED IN THE IBC TABLES 601 AND 602, AND THE REMAINING INFORMATION LISTED ON THIS SHEET WILL BE REVIEWED DURING A LATER PHASE OF THIS PROJECT. 2. SHEETS G2.2.1 AND G2.2.2: THE LIFE SAFETY PLANS INDICATED ON THESE SHEETS WILL BE REVIEWED DURING A LATER PHASE OF THIS PROJECT. 3. SHEETS S1.1 AND S1.2: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. PLEASE REVISE. 4. SHEET S1.1; GENERAL STRUCTURAL NOTES (LOADS): PER THE IBC TABLE 1607.1, CONCENTRATED LIVE LOADS MUST FOLLOW THE DESIGN AS INDICATED IN NOTE a. PLEASE VERIFY IN THE CALCULATIONS ALL UNIFORM AND CONCENTRATED LOAD OPTIONS HAVE BEEN CONSIDERED IN THE DESIGN. 5. SHEET S2.1.0 (FOUNDATION PLAN); SHEET PC-100 (KEY PLAN): THESE PLANS INDICATE DIFFERENT NORTH ARROWS. PLEASE COORDINATE. 6. SHEETS S2.1.1A AND S2.1.1B: PLEASE ADD NORTH ARROWS TO THE PLANS. 7. SHEET S2.1.1B (FOUNDATION PLAN); STRUCTURAL CALCULATIONS (SHEET 17): THE CALCULATIONS INDICATE THE WALL FOOTING IS 12" THICK X 2'-6" WIDE, WHILE THE WALL FOOTING SCHEDULE ON SHEET S2.1.1B INDICATES 1'-0" HT. AND 2'-0" WIDTH (WF6). PLEASE COORDINATE. 8. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
| 05/02/2016 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/04/2016 | CPIERCE1 | OUT TO CUSTOMER | Completed |