Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T15PI00012
Review Name: PIA - SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/04/2015 | LINZUNZA | UTILITY CLEARANCES | COT STREETS DIVISION | Denied | |
| 06/04/2015 | LINZUNZA | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Denied | |
| 06/04/2015 | LINZUNZA | UTILITY CLEARANCES | PC WASTEWATER MGMT | Denied | |
| 06/04/2015 | LINZUNZA | UTILITY CLEARANCES | QUEST COMMUNICATION | Denied | |
| 06/04/2015 | LINZUNZA | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Denied | |
| 06/04/2015 | LINZUNZA | UTILITY CLEARANCES | COX COMMUNICATION | Denied | |
| 06/04/2015 | LINZUNZA | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Denied | |
| 06/04/2015 | LINZUNZA | UTILITY CLEARANCES | EL PASO NATURAL GAS | Denied | |
| 06/04/2015 | LINZUNZA | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Denied | |
| 06/09/2015 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Denied | The landscape planting and irrigation are approved, but the hardscape requirements have changed. Please contact Frank Dillon at Development Services or Gary Wittwer at TDOT for Interim Streetscape Design Policy. |
| 06/23/2015 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Approv-Cond | June 23, 2015 SUBJECT: The Hub At Tucson Phase II PIA Plan U-2015-010, DSD Activity #T15PI00012 PROJECT REVIEWER: Zelin Canchola, DOT Review Section DOT Review Section has reviewed the PIA Plan for Traffic Engineering. Conditional approval is granted with the following changes/redlines on sheet 5 of 12 1. Add speed limit for Alley to 15 mph on note 9 2. Show red curb along Tyndall Ave for no parking areas. Include quantities. If you have any questions I can be reached at 837-6659 or zelin.canchola@tucsonaz.gov |
| 06/29/2015 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Approv-Cond | SUBJECT: The Hub at Tucson Phase II PROJECT REVIEWER: Richard Leigh, TDOT, TDOT Eng. Review RESUBMITTAL REQUIRED: TDOT Permits Section has reviewed the subject PIA paving plan and recommends a conditional approval at this time. The following comments need to be addressed prior to submitting mylars plan set for signatures. Redlined drawings must be returned with subsequent submittal. 1. Include the plan number "U-2015-010" in the title block of each sheet. 2. Sheet 1: Include the PIA activity number "T15PI00012 on cover sheet. 3. Sheet 1: Revise Arizona Blue Stake label with latest version. Arizona 811 has a new, updated label for engineering prints and plans and it is now available in JPG, PDF and DXF formats on their website under "Resources" - http://www.arizona811.com/resources. 4. Sheet 3: Indicate the radii of the proposed curb returns for the driveway on Tyndall . 5. Sheet 4: Provide a right and left profile of the proposed pavement in the public alley. 6. Sheet 4: The City of Tucson Department of Transportation will not be responsible for the maintenance of the proposed reinforced concrete slab. Please Refer to redline plans for additional comments and comment details. If you have any questions, I can be reached at 837-6647 or at Richard.Leigh@tucsonaz.gov |
| 07/16/2015 | LINZUNZA | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | |
| 07/16/2015 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Denied | July 9, 2015 PIA Hub at Tucson Phase II - T15PI00012 PIA Reviewer: Jim Femling - Streets & Traffic Maint. Comments: TDOT Streets & Traffic Maint. has reviewed the project and recommends resubmittal. Page 4 of 12 - Cannot have a permanent solid waste container blocking alley access. If you have any questions I can be reached at james.femling@tucsonaz.gov. |
| 07/16/2015 | LINZUNZA | PIA COORDINATOR | OUT TO CUSTOMER | Completed |