Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T15CM05114
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/24/2015 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
07/24/2015 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
07/27/2015 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | #1. Please provide for disconnecting means within site of transformer T1, for the primary feeder, or provide field marking on the transformer and lockable disconnect switch as required per NEC art. 450. 14. #2. Please provide a complete panel schedule including load calc's for existing panel A. #3. Please verify voltages for both transformers shown as step down. #4. Please show the conduit, conductor, sizes and types for all the receptacles shown that are new, existing, or refed to the new panel L1. |
07/27/2015 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. SHEET A0.0: PLEASE REVISE THE ELECTRICAL DRAWING NUMBERS IN THE INDEX TO MATCH THE DRAWINGS PROVIDED. 2. SHEET A1.0D: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. PLEASE REVISE THE SPECIFICATIONS. 3. SHEET A1.0; KEYNOTES: NOTE 5 INDICATES AN ADA RAMP WITH A MAXIMUM SLOPE OF 1:8 PER 15.1.4 EXCEPTIONS 1 AND 2. PLEASE PROVIDE WHICH CODE THIS REFERENCES. THE ACCESSIBILITY ON THIS PROJECT FALLS UNDER THE 2010 ADAAG. 4. SHEET A1.0; KEYNOTES: NOTE 15 REFERENCES A NEW WOOD CANOPY. IS THIS PART OF THIS PROJECT? IF SO, PROVIDE STRUCTURAL CALCULATIONS, DRAWINGS, AND SPECIFICATIONS FOR THE CANOPY. 5. SHEET A3.1: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. PLEASE REVISE THE SPECIFICATIONS. 6. SHEET S1.0; DETAIL 101: NOTES INDICATE DRAWING REVISIONS ON 7/13/15. PLEASE CLARIFY. 7. GENERAL: PLEASE PROVIDE STRUCTURAL CALCULATIONS FOR THE CAROUSEL FOUNDATION DESIGN. 8. GENERAL: IS ANY NEW SITE LIGHTING REQUIRED FOR THIS PROJECT? IF SO, PLEASE INDICATE ON THE PLANS. PROVIDE FOUNDATION DETAILS AND CALCULATIONS AS REQUIRED. 9. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
07/27/2015 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
08/05/2015 | AROMERO4 | OUT TO CUSTOMER | Completed |