Permit Number: T15CM03555
Parcel: 12512080A

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T15CM03555
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/30/2015 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Reqs Change Restroom exhaust fans to run during business hours, connecting to the light switch will not comply with mechanical code see note #7 Plan Sheet M2.
06/30/2015 ROBERT SHERRY WATER REVIEW Reqs Change Tucson Water limits a 5/8" water meter to a maximum demand of 15 GPM. A demand of 18 GPM will require the installation of a 3/4" water meter. [Initial comment: Provide the size and serial number of the water meter serving this suite, the size of the backflow preventer associated with the water meter, and the total water demand served by the water meter. Reference: Section 107.2.1, IBC 2012.]
06/30/2015 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Verify that the addition of the reduced pressure backflow prevention assembly will not adversely affect the minimum residual pressure of 15 PSI for the fixtures in this suite.
06/30/2015 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Completed
07/09/2015 AROMERO4 BUILDING-COMMERCIAL REVIEW Needs Review