Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T15CM02532
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/15/2015 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 04/15/2015 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 04/16/2015 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 04/16/2015 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | Section C101.4.3, IECC 2012 requires relocated HVAC equipment to meet the current energy code. Include the relocated A/C unit in the mechanical compliance analysis. |
| 04/16/2015 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 04/16/2015 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 04/16/2015 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
| 04/16/2015 | RSHERRY1 | WWM | REVIEW | Passed | No wastewater plumbing. |
| 04/24/2015 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. SHEET D1 (SECOND FLOOR PLAN); FLOOR PLAN KEY NOTES: NOTE D15.1 INDICATES TO REMOVE A MOP SINK. IS THIS TO BE REPLACED (IS IT REQUIRED BY THE IBC)? 2. SHEET A1 (FIRST FLOOR PLAN); SHEET S1.0 (FLOOR FRAMING PLAN): PLEASE COORDINATE THE ARCHITECTURAL AND STRUCTURAL PLANS (NUMBER OF COLUMNS, LOCATION OF COLUMNS). 3. SHEET S2.0; SECTION A: IS THE SIZE OF THE NEW TUBE ON THE BOTTOM OF THE EXISTING JOIST INDICATED ON THE DRAWINGS? PLEASE VERIFY. 4. STRUCTURAL CALCULATIONS: WAS THE WEIGHT OF THE NEW STEEL PLATES IN THE WALLS AND ON THE FLOOR ADDED TO THE LOADS SUPPORTED BY THE NEW FLOOR BEAMS? PLEASE VERIFY. 5. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
| 04/24/2015 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed |