Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T14PI00005
Review Name: PIA - SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/02/2014 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Approv-Cond | Need to see irrigation plan. NOTE: you can not place private irrigation lines under public roadway. |
| 05/06/2014 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Approv-Cond | PLANS # i-2014-004 ACTIVITY NUMBER: PLANS # i-2014-004 ACTIVITY NUMBER: T14PI00005 PROJECT NAME: Sierra Morado Unit 3 / Roscommon Pl. PROJECT ADDRESS: Drexel Rd. & Roscommon Pl. PROJECT REVIEWER: Matthew Geweke, Traffic Eng. Tech Conditional Acceptance: Traffic Engineering recommends conditional approval of the PIA Plan; therefore a revised PIA Plan is not necessarily required for re-submittal plans but the following items must be revised or added to the plan. Just an email response with an exchange of PDF's is required in lieu of a re-submittal. 1. See redline comments on Shts 4 & 5 on the submitted drawing. Please address the redline comments and signing changes as appropriate. [1] + replace if missing [3] + refresh as determined by Traffic Eng. [4] + Drexel Rd [5] - R1-1 Stop sign [6] + direct drive square tube post. [ ] + abbreviated signing note [7] + NP, NP Begins, NP Ends signs as appropriate Please email me at Matthew.Geweke@tucsonaz.gov with a PDF of the corrected redline Shts showing the revisions of these requested changes, and Traffic Eng. will accept/approve these plans. I can also be reached at (520) 837-6665 with any questions. Thanks |
| 05/29/2014 | IMEDINA1 | UTILITY CLEARANCES | COT STREETS DIVISION | Completed | |
| 05/29/2014 | ZCANCHO1 | DOT ENGINEERING | REVIEW | Approv-Cond | May 28, 2014 SUBJECT: Sierra Morado Unit 3 - Roscommon Pl. - T14PI00005 PROJECT REVIEWER: Zelin Canchola, DOT, TDOT Permit Section RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and recommends a conditional approval at this time. The following comments need to be addressed prior to submittal of the mylars for signature. Please return redlined drawings with next submittal reference PIA activity number on all correspondences. 1. Include the plan number "I-2014-004" in the title block of each sheet. 2. Include Development Services Department PIA activity number "T14PI00005 on cover sheet. 3. Sheet: 1 Paving Note 15: Replace phone number from 237-7386 to 520-791-3191. 4. Sheet 1: Paving Note 20: Replace Traffic Engineering to COT Department of Transportation Permit Center. 5. Indicate the placement of a thickened pavement edge or concrete header at pavement termination on Arolla Pine Ave south of Roscommon Place and on Roscommon Place west of Arolla Ave. 6. Indicate placement of post barricades Per PC/COT SD105 at pavement termination on Arolla Pine Ave south of Roscommon Place and on Roscommon Place west of Arolla Ave. 7. Has the COT PDSD approved the subphasing of this project? Please submit any correspondence of PDSD approval or concurrence of the subphasing Please Refer to redline plans for additional comments and comment details. If you have any questions, I can be reached at 837-66476659 or Zelin.Cancholla |
| 05/29/2014 | IMEDINA1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Completed | |
| 05/29/2014 | IMEDINA1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Completed | |
| 05/29/2014 | IMEDINA1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Completed | |
| 05/29/2014 | IMEDINA1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Completed | |
| 05/29/2014 | IMEDINA1 | UTILITY CLEARANCES | COX COMMUNICATION | Completed | |
| 05/29/2014 | IMEDINA1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Completed | |
| 05/29/2014 | IMEDINA1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Completed | |
| 05/29/2014 | IMEDINA1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Completed | |
| 06/04/2014 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Approv-Cond | We have reviewed this plan and have approved is conditionally based on addressing these comments: 1. Sheet 1 - Note 15 - Change phone number for Median Islands to 791-3154 and Paul Rosenboom's number to 837-6796. 2. Sheet 1 - Note 22 - Change Ernie Encinas phone number to 837-6782. 3. Sheet 2 and 3 - We have concern regarding all slopes greater than 2:1 in the ROW eroding. Was grouted rip rap considered? No further comments Marc Avery Lance Peterson, P.E. Streets and Traffic Maintenance |
| 06/30/2014 | IMEDINA1 | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | |
| 06/30/2014 | IMEDINA1 | PIA COORDINATOR | OUT TO CUSTOMER | Needs Review |