Permit Number: T14CM06599
Parcel: 117062000

Review Status: Completed

Review Details: REVISION - - 2ND

Permit Number - T14CM06599
Review Name: REVISION - - 2ND
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/31/2017 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. GENERAL: THE STRUCTURAL ENGINEER OF RECORD STAMPED THE SHOP DRAWINGS FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT OF THE PROJECT AND GENERAL COMPLIANCE WITH THE INFORMATION GIVEN IN THE CORRECT DOCUMENTATION ON 6/20/16. THE TRUSS LAYOUT PLANS OF THE NORTH WING, WEST WING, AND EAST WING INDICATE REVISIONS ON 10/19/16, 11/9/16, 11/17/16, 11/18/16, AND 11/28/16, AND ALSO INDICATE AS-BUILT LAYOUT ON 12/12/16. THE STRUCTURAL ENGINEER OF RECORD NEEDS TO REVIEW THESE LAYOUT PLANS ALONG WITH THE LIGHT GAGE STEEL TRUSS DESIGN DRAWINGS AND DETAILS (AS-BUILTS DATED 12-28-16), AND RESTAMP USING THE CURRENT DATE.
2. SHEET s2.7A: THIS SHEET IS INCLUDED IN THE REVISED DRAWING SET, BUT NO MENTION IS MADE IN THE NARRATIVE OF THOSE CHANGES. PLEASE VERIFY.
3. SHEET a1.6B: THIS SHEET IS NOT INCLUDED IN THE REVISED DRAWING SET, BUT COMMENTS WERE MADE IN THE NARRATIVE FOR THAT SHEET. PLEASE VERIFY.
4. SHEET a1.7B: THIS SHEET IS NOT INCLUDED IN THE REVISED DRAWING SET, BUT COMMENTS WERE MADE IN THE NARRATIVE FOR THAT SHEET. PLEASE VERIFY.
5. SHEET a1.8B: THIS SHEET IS NOT INCLUDED IN THE REVISED DRAWING SET, BUT COMMENTS WERE MADE IN THE NARRATIVE FOR THAT SHEET. PLEASE VERIFY.
6. SHEETS a10.2, a10.3, AND a10.4: THESE SHEETS ARE INCLUDED IN THE REVISED DRAWING SET, BUT NO MENTION IS MADE IN THE NARRATIVE OF THOSE CHANGES. PLEASE VERIFY.
7. SHEET i3.2: THIS SHEET IS INCLUDED IN THE REVISED DRAWING SET, BUT NO MENTION IS MADE IN THE NARRATIVE OF THOSE CHANGES. PLEASE VERIFY.
8. SHEET i4.4: THIS SHEET IS INCLUDED IN THE REVISED DRAWING SET, BUT NO MENTION IS MADE IN THE NARRATIVE OF THOSE CHANGES. PLEASE VERIFY.
9. SHEET i5.0: THIS SHEET IS INCLUDED IN THE REVISED DRAWING SET, BUT NO MENTION IS MADE IN THE NARRATIVE OF THOSE CHANGES. PLEASE VERIFY.
10. GENERAL: IT APPEARS FROM THE REVISIONS DATED ON THE DRAWINGS THERE WERE CHANGES MADE TO THE DRAWINGS THAT WERE NOT SUBMITTED TO THE CITY OF TUCSON FOR REVIEW. PLEASE PROVIDE A LIST INDICATING THE SPECIFIC NATURE OF THE CHANGES, THE SPECIFIC SHEETS THAT WERE REVISED, AND THE DATES OF ALL THE REVISIONS.
11. GENERAL: PLEASE PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
01/31/2017 KEN BROUILLETTE FIRE REVIEW Approved
02/01/2017 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change 1. The submitted drawings contain non-clouded entries that are not part of the drawing set approved on 5/10/2016. Identify all of the revisions made since the initial approval
2. The modifications letter states that the "relief hood for elevator" has been removed from sheet m1.9 but no relief hood is shown on the original m1.9, approved on 5/10/2016.
02/01/2017 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. The submitted drawings contain non-clouded entries that are not part of the drawing set approved on 5/10/2016. Identify all of the revisions made since the initial approval
2. Provide listing information for the flow control device installed on the new fixture drain for the pool cover (keynote #56, p1.5). Reference: Section 303.4, IPC 2012.
3. Clarify how the pool cover is to be drained (i.e. where is the air gap located?). Reference: Section 802.1.4, IPC 2012.
4. The modifications letter states that a floor sink has been added to the patio bar (p1.6b); two were shown on the approved plans and two are shown in the same locations on the revised plans: where is it?
02/10/2017 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
02/15/2017 FRODRIG2 WWM REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
03/13/2017 KROBLES1 OUT TO CUSTOMER Completed