Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T14CM05660
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/28/2014 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 08/28/2014 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 08/28/2014 | RONALD BROWN | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 08/29/2014 | LHANLY1 | WWM | REVIEW | Passed | |
| 08/29/2014 | JASON GREEN | ENGINEERING | REVIEW | Approved | August 29, 2014 FLOODPLAIN USE PERMIT NO.: T14OT01114 ADDRESS: 3352 E Speedway Blvd Tucson, Arizona 85716 The applicant is authorized to use a portion of the City of Tucson Flood Hazard Area per the Christmas Ave Wash delineation, specifically described as: For the purpose of an interior demo to an existing non-conforming building The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard Area Regulations, and is bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, UDC, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations require application for, review and approval of an additional Floodplain Use Permit. This floodplain use permit is issued with the following 8 conditions: 1) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 2) This Floodplain Use Permit is issued concurrently with the improvement plans/permit. Copies of these documents shall be kept in a readily accessible location on site at all times. 3) Any future permanent, freestanding walls or other structures shall have separate floodplain use permit applications submitted to this office for review and approval. 4) An application/processing fee of $50.00 (submittal fee) must accompany each future request for work to be authorized under this floodplain use permit. Engineering study review fees of $150.00 may be imposed based upon the fee schedule in the current floodplain ordinance. 5) The associated improvements are with permit activity number T14CM05660. 6) The applicant attests to the fact that the plans and documents submitted represent all of the improvements that will be done to the existing building, and that all additions, improvements or repairs to the building are included in the construction plans and/or documents herewith. No other improvements, repairs, reconstruction, additions or remodeling have been made to the structure that is not indicated in the attached plans and/or documents. 7) Renewal of this permit will require a new application, review and approval of that application by the City of Tucson Planning & Development Services Department, Engineering Division. This permit may be renewed for up to one year at the sole discretion of the City Engineer or designated representatives. 8) This permit is specific to the improvements for 3352 E Speedway Blvd as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit. APPLICANT NAME: Chuck Meyers ADDRESS: 6409 E Calle Alkaid Tucson, AZ 85710 PHONE: 520-869-4245 (EXPIRATION DATE) Month: 08 Day: 29 Year: 2015 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
| 08/29/2014 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
| 08/29/2014 | LHANLY1 | FIRE | REVIEW | Passed | interior demo only. new drawings being done for ti |
| 08/29/2014 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 08/29/2014 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 08/29/2014 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/09/2014 | CPIERCE1 | APPROVAL SHELF | Completed |
| 09/09/2014 | SHANAE POWELL | OUT TO CUSTOMER | Completed |