Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T13PI00027
Review Name: PIA - SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/08/2014 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Denied | We have reviewed this plan and have the following comments: 1. Sheet 2 - Note 2 - Please change the Median Island Office phone number to 791-3154 and change Paul Rosenboom's phone number to 837-6796. 2. Sheet 4 - The plan appears to show a ponding area on the pedestrian path. Please make sure that there is positive drainage and that there is not a ponding condition created. 3. Sheet 6 - Detail 4 - There is concern witht he cross slope taiking the runoff overr the ped path that there is a potential for erosion of the path. Please address potential erosion of the path. No further comments. Reviewed by Marc Avery. |
| 01/15/2014 | RLEIGH1 | UTILITY CLEARANCES | COT STREETS DIVISION | Approved | |
| 01/15/2014 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Denied | January 14, 2014 SUBJECT: Public Paving Plans for Fiandaca Blvd. and 34th St - Meridian I-19 Access PROJECT REVIEWER: Richard Leigh, DOT, Permits and Codes Section RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval at this time. The following comments need to be addressed prior to in the subsequent review submittal. Please return redlined drawings with next submittal. 1. Include the plan number "I-2010-020" in the title block of each sheet. 2. Include Development Services Department PIA activity number "T13PI00027 "on cover sheet. 3. Include Fiandaca Boulevard and 34th Street in plan title. 4. Sheet 1: Include Developers information on cover sheet. 5. Sheet 2: Please include the following note. This project is located in an archaeological sensitivity zone. An archaeological monitor will be required to be on-site during any excavation operations unless a waiver has been issued. Monitoring reports are to be submitted to the Historic Preservation Office, City Of Tucson, P.O. Box 27210, Tucson, Az 85726.** contact Jonathan Mabry at 520-837-6968 or jonathan.mabry@tucsonaz.gov with any questions. 6. Sheet 3 & 4: Clearly show and label existing and proposed right-of-way limits in plan views. 7. Sheet 3 & 4: Delineate limits of PIA work in plan views. The City will not be responsible for inspection on State land or private property. 8. Sheet 4, Note 12: Indicate compaction requirements for asphalt path subgrade. Per SSPI Sec. 205-3.04, the minimum compaction for subgrade when placing asphaltic concrete directly on subgrade is a 100% percent of the maximum density. 9. .Provide center line data for the proposed roadways alignments. 10. Indicate the placement of survey monuments at the point of curvature and roadway intersection along roadway center line. 11. Indicate the placement of a six foot wide asphalt pathway from El Puente Lane and 34th Street per adopted ordinance No. 11112. 12. Address comments on redline plan set. Responses can be noted on redline drawings. Please Refer to redline plans for additional comments and comment details. If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov |
| 01/15/2014 | RICHARD LEIGH | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | Please submit Utility Receipt letters with next Submittal. |
| 01/15/2014 | RLEIGH1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Approved | |
| 01/15/2014 | RICHARD LEIGH | PIA COORDINATOR | OUT TO CUSTOMER | Completed | Please submit Utility Receipt letters with next Submittal. |
| 01/15/2014 | RLEIGH1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Approved | |
| 01/15/2014 | RLEIGH1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Approved | |
| 01/15/2014 | RLEIGH1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Approved | |
| 01/15/2014 | RLEIGH1 | UTILITY CLEARANCES | COX COMMUNICATION | Approved | |
| 01/15/2014 | RLEIGH1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Approved | |
| 01/15/2014 | RLEIGH1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Approved | |
| 01/15/2014 | RLEIGH1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Approved | |
| 12/11/2013 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Approved | |
| 12/11/2013 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Denied | PIA: I-2013-020 ACTIVITY NUMBER: T13PI00027 PROJECT NAME: Meridian i-19 Access (ADOT gated driveway) PROJECT ADDRESS: 34th St. & Fiandaca Rd. PROJECT REVIEWER: Matthew Geweke, Traffic Eng Tech Non-Acceptance: Traffic Engineering does not recommend approval of the PIA Plan; therefore a revised PIA Plan is necessarily for re-submittal. The following items must be revised or added to the plan. Please include a brief response letter with the next submittal that states how all comments have been addressed and the original redlined set of plans for back checking. - Sht 1: Fiandaca Rd. is not a City of Tucson street. Please define city limits and right of way, also ADOT jurisdictional property lines and right of way. - Sht. 2: please update Pavement Marking 2 Keynote #12 (see attached pg.) - Sht. 3 Note 11: please replace all existing signs with new signs. You will also need to add the Signing Notes somewhere in the plans please. (see attached pg.) - Suggest the S end of Fiandaca Rd proposed intersection improvements require "End of Rd" markers (OM4-3), Arrow Rt (W1-6R) and 'No Parking' signs? - Suggest S-bound Fiandaca Rd now require Curve Adv Warning (W1-1R) sign since this really is a 90` elbow intersection? Thank you, If you have any questions, I can be reached at 837-6665 or email: Matthew.Geweke@tucsonaz.gov |