Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/05/2013 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
06/05/2013 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Provide 0.7 CFM / Square foot exhaust for the kitchen (each appliance that does not require a Type II hood is considered to occupy at least 100 square feet). Reference: Sections 403.3 and 507.2.2, IMC 2012. |
06/05/2013 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Verify the size of the hydromechanical grease interceptor - at 30" in total height, it won't fit under the sink. 2. External flow control devices are not required for the specified grease interceptor and thus constitute obstructions in the waste piping. 3. Provide a thermostatic mixing valve for each lavatory that conplies with ASSE 1070. |
06/05/2013 | ROBERT SHERRY | WATER | REVIEW | Approved | |
06/05/2013 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
06/05/2013 | JASON GREEN | ENGINEERING | REVIEW | Approved | |
06/05/2013 | KEN BROUILLETTE | FIRE | REVIEW | Approved | |
06/05/2013 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
06/11/2013 | CPIERCE1 | WWM | REVIEW | Needs Review | |
06/11/2013 | CPIERCE1 | ELECTRICAL-COMMERCIAL | REVIEW | Needs Review |