Permit Number: T13CM01691
Parcel: 11310001A

Address:
1545 E COPPER ST

Review Status: Completed

Review Details: RESUBMITTAL - TI ALL

Permit Number - T13CM01691
Review Name: RESUBMITTAL - TI ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/24/2013 RONALD BROWN BUILDING-COMMERCIAL REVIEW Approved
04/29/2013 ROBERT SHERRY WATER REVIEW Approved
04/29/2013 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied Revise the island venting shown in detail A/P1.1 to show the low point of the vent connecting to the drain downstream of the fixture drain. Reference: Section 916.2, IPC 2012. [Original comment: Verify that all of the vents rise vertically to at least 6" above the flood rims of the fixtures they protect prior to running horizontally. Reference: Section 905.4, IPC 2012.]
04/29/2013 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved
05/09/2013 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
05/14/2013 SHANAE POWELL OUT TO CUSTOMER Completed
05/14/2013 CPIERCE1 REJECT SHELF Completed