Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T12CM05572
Parcel: 13819045B

Review Status: Completed

Review Details: RESUBMITTAL - TI ALL

Permit Number - T12CM05572
Review Name: RESUBMITTAL - TI ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/14/2012 RONALD BROWN BUILDING-COMMERCIAL REVIEW Denied RESPONSE TO COMMENTS ARE NON-RESPONSIVE. PLEASE PROVIDE CORRECTIONS AS PER EACH COMMENTS LISTED BELOW:

1. Please provide partial toilet plans and interior elevations for all the toilet rooms showing all accessible requirements: dimensions (vertical and horizontal), clearances, accessories, signage, fixtures and required finishes as required by ICC A117.1, 2003 Edition.
2. Please provide individual partial plans, sections and elevations for all the different types of stairs (3 sets) showing all dimensions, risers and treads, handrails and landings. Please provide handrail elavations.
SHEET A1.2
3. The stage ramp is non-compliant as per the 2006 IBC, Section 405.7; 5' landings and handrails.
a. Please provide an elevation of the handrails as per ICC A117.1, Section 505.10.1.
SHEET A2.0
4. Show section through wrought iron railing at the choir loft and structural calculations for requirements os the 2006 IBC, Section 1607.7.1.
a. Guard rails are to be a minimum of 3'-6" high. Please revise your notes calling for 36".
SHEET A3.0
5. The City of Tucson actual lettering size for construction drawings is 3/32" upper and lower case, actual not font size.
Please revise this sheet and resubmit.
END OF REVIEW
11/14/2012 FRODRIG2 WWM REVIEW Needs Review
11/14/2012 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Comment not resolved; a drain line may not connect to a vent. [Clarify the connection of the drain for lavatory P-1A to water closet P-2A as shown in detail A/P2.0; is the lavatory drain connecting above or below the trap arm for the water closet?]
2. change the 4" CO for P-2 which has a 3" drain (C/P2.0) [Clarify the number of 4" cleanouts shown in detail B/P2.0 for the water closets; the note says 4" WCO (TYP. 6) but this appears to conflict with the other notes in the detail that indicate that the drains for five of water closets are 3" in size.]
3. Offsetting horizontally prior to reaching 6" above the flood rim of the fixture is not permissible except where there are structural problems. [Clarify the note in the plumbing schedule for the mop sink, P6, which says "vent underground".]
11/14/2012 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved
11/14/2012 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved