Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T12CM05550
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/01/2012 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | 1. As per the 2006 IBC, Table 602, the most easterly located Gazebo must be 10'-0" from the property line. Is is currently 8;-0" from the property and will required a 1 hour ratred partition on the East side. 2. On page 5 od the calculations, at the top most detail, there is anote about a 6x10 eave. Can not find this sixze eave on the framing plans. Please explain. END OF REVIEW |
| 10/01/2012 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/04/2012 | CINDY AGUILAR | REJECT SHELF | Completed |