Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T12CM00390
Parcel: 13502134H

Address:
7090 E 22ND ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T12CM00390
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/26/2012 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied Provide a drawing that clearly shows how and where the 3"vent connects to the gravity grease interceptor and the locations for the cleanouts for the building sewer and interceptor. [Third comment: Comment not resolved. The drawings now consistently indicate the size of the proposed grease interceptor and that there is to be a 3" vent for the interceptor but the drawings still do not indicate how or where the vent connects to the interceptor and there is no information regarding the required cleanouts for the building sewer or for the interceptor.] [Second Comment: Clarify the proposed capacity and installation of the gravity grease interceptor. The civil drawing, UT01, calls for a 1250-gallon unit, sheets P3.2 and P3.4 call out a 1500-gallon unit and the submitted cut sheets are for a 1300-gallon unit. In addition, the calculations shown on sheet P3.4 actually indicate a 1000-gallon interceptor is an acceptable size. No drawings show how the interceptor is to be vented and there is no information regarding the required cleanouts.] [Original comment: Provide sufficient information to show that the installation of the proposed gravity grease interceptor complies with the requirements of Sections 1009.0, 1014.1, and 1014.3, UPC 2006. (A note on sheet UT01, Utility Plan, refers to the plumbing sheets for this information.)]