Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T11OT00114
Parcel: 10510097A

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T11OT00114
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/26/2011 JASON GREEN ENGINEERING REVIEW Approved February 10, 2011
FLOODPLAIN USE PERMIT # T11OT00114
PROJECT ADDRESS: 831 E Limberlost Drive Tucson AZ 85719
APPLICANT'S NAME: A.C. Tsang Engineering Group, Inc.
PROPERTY OWNER: Antony Tsang

The applicant is authorized to use a portion of the mapped regulatory 100-year floodplain per the submitted Drainage Report (Bogardus Engineering, LLC, 24JUN10, revised 13SEP10), specifically described as:

Parcel 105-10-097A; HAYNES RILLITO E190.20' M/L W300.20' N342.66' S372.66' LOT 11

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following 9 conditions apply to this permit:
1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes or further disturbance within the floodplain area occurs other than that outlined in this application and/or on the Tentative Plat and Grading Plan. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from the construction activity within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.
2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
3) All work shall conform to the approved Tentative Plat and future grading plan sheets and details which are made part of this permit.
4) The permit is for an encroachment analysis for future building pad locations (and finished pad elevations) for a new Flexible Lot Development that is considered infill and for the construction of a new concrete channel with associated detention/retention basin and erosion hazard setback reduction per the accepted Drainage Report.
5) Certification from a AZ registered land surveyor is required at grading plan stage prior to final grading plan inspection approval to verify that the proposed pads meet the minimum height requirements as shown for floodplain verification.
6) Future buildings on Lots 4, 5, 6, 7, and 8 are restricted to the finish floor elevation (FFE) requirements per the Drainage Report. Pad elevations and finish floor elevations for the future buildings will be required to have a new floodplain use permit application and associated elevation certificates for each structure. Any deviation will require a new Drainage Report and encroachment analysis.
7) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times.
8) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.
9) There shall be no stockpiling material, or storage of vehicles, other than that which is accepted by COT and as shown on the approved plans. There shall be no stockpiling or disturbance outside of disturbance limits. Construction material and vehicles shall be promptly removed once improvements are complete.
10) See the associated activity S10-027 and the required future grading plan activity number.

This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Planning and Development Services Department, and Engineering Division.

APPLICANT/CONTRACTOR: A.C. Tsang Engineering Group, Inc.
ADDRESS: 4626 E Ft Lowell Rd Suite S, Tucson, Arizona 85712
PHONE: (520)-325-0979
OWNER: Antony and Veronica Tsang
ADDRESS: 4626 E Ft Lowell Rd Suite S, Tucson, Arizona 85712
PHONE: (520)-325-0979

(EXPIRATION DATE) Month: 02 Day: 10 Year: 2012

SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.

Final Status

Task End Date Reviewer's Name Type of Review Description
03/11/2014 SUE REEVES APPROVAL SHELF Completed
03/11/2014 CPIERCE1 OUT TO CUSTOMER Completed