Review Date Reviewer's Name Type of Review Description Status Comments
01/03/2012 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. SHEET T1; CODES: REMOVE ALL REFERENCES TO THE RESIDENTIAL CODE AND INCLUSIVE HOME DESIGN ORDINANCE. ADD THE ACCESSIBILITY CODE ICC/ANSI A117.1-2003.
2. SHEET T1; CODES: REMOVE ALL REFERENCES TO CODES THAT ARE NOT PERTINENT TO THIS PROJECT (ELECTRICAL, MECHANICAL, PLUMBING, FUEL GAS, EXISTING BUILDING, ETC.).
3. SHEET A; GENERAL NOTES: PROVIDE MATERIAL PROPERTIES FOR CONCRETE AND CONCRETE REINFORCEMENT.
4. SHEET A; BUILDING LOADS: PROVIDE THE GEOTECHNICAL INFORMATION USED FOR THE FOUNDATION DESIGN (WRITTEN REPORT OR ASSUMED VALUE PER THE IBC.).
5. SHEET A; GENERAL NOTES: REMOVE ALL REFERENCES TO ORGANIZATIONS AND CODES THAT ARE NOT PERTINENT TO THIS PROJECT (WELDING, ICBO/UBC, SOUTHERN BUILDING CODE, BOCA, NATIONAL CODE OF CANADA, ETC.).
6. SHEET A1: PROVIDE A DETAIL FOR THE FOUNDATION AT THE SLAB EDGE.
7. SHEET A1: PROVIDE A DETAIL FOR THE FOUNDATION AT THE ENDWALL COLUMNS.
8. SHEET A1.2 (CROSS SECTION); STRUCTURAL CALCULATIONS: THE COLUMN SECTION INDICATED ON SHEET A1.2 (8X3.5, 16 GA.) DOES NOT APPEAR IN THE CALCULATIONS (8X3.5, 14 GA. OR 8X2.5, 14 GA.). CLARIFY.
9. GENERAL: THE ROOF PANEL AND WALL PANEL SIZES ARE NOT INDICATED ON THE DRAWINGS. PROVIDE PER THE CALCULATIONS.
10. GENERAL: PLANS, ELEVATIONS, SECTIONS, DETAILS, NOTES, SPECIFICATIONS, AND MATERIAL PROPERTIES FOR THE SHADE STRUCTURE MUST BE INCLUDED ON FULL SIZE SHEETS.
11. GENERAL: PROVIDE A CODE ANALYSIS ON THE DRAWINGS FOR BOTH STRUCTURES, INDICATING OCCUPANCY CLASSIFICATION, OCCUPANCY LOAD, AND CONSTRUCTION CLASSIFICATION.
12. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
01/04/2012 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Passed
01/04/2012 ROBERT SHERRY ELECTRICAL-COMMERCIAL REVIEW Passed No electrical work shown on drawings.
01/04/2012 RSHERRY1 WWM REVIEW Passed No new plumbing fixtures.
01/04/2012 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Passed
01/04/2012 ROBERT SHERRY WATER REVIEW Approved
01/04/2012 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Approved
12/22/2011 MARTIN BROWN FIRE REVIEW Denied Fire Comments:

Provide a fire hydrant or fire sprinklers per IFC 508.5.1 as amended.

Final Status

Task End Date Reviewer's Name Type of Review Description
01/09/2012 CPIERCE1 REJECT SHELF Completed