Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T11CM01873
Parcel: 110034830

Review Status: Completed

Review Details: COMMERCIAL - NEW

Permit Number - T11CM01873
Review Name: COMMERCIAL - NEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/16/2011 DAVE MANN FIRE REVIEW Approved
06/20/2011 RONALD BROWN ADA REVIEW Passed
06/29/2011 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. SHEET 3; PLAN 1: NOTES 3 AND 4 INDICATE STAMPED AND SIGNED CALCULATIONS AND SHOP DRAWINGS ARE TO BE SUBMITTED FOR REVIEW. CALCULATIONS WERE RECEIVED, BUT NOT SHOP DRAWINGS. CLARIFY.
2. SHEET 3; PLAN 1: NOTE 6 INDICATES A GEOTECHNICAL REPORT IS TO BE USED. PROVIDE. THE CALCULATIONS DO NOT INDICATE SOIL VALUES USED.
3. SHEET 3; STRUCTURAL CALCULATIONS: A FRAMING PLAN INDICATING ROOF DECK, POST, AND GIRDER SIZES SHOULD BE INCLUDED ON THE DRAWING.
4. SHEET 3 (SECTION 4); STRUCTURAL CALCULATIONS (PAGE 3): THE FOOTING INDICATED IN THE CALCULATIONS IS A 2'-0" DIAMETER X 3'-0" DEEP (MIN.) FOOTING, WHILE SECTION 4 INDICATES A 3'-0" (SQUARE?) FOOTING. COORDINATE.
5. SHEET 3; STRUCTURAL CALCULATIONS (PAGE 3): THE PLATES AND WELDS INDICATED IN THE CALCULATIONS SHOULD BE SHOWN ON THE DRAWING.
6. GENERAL; SHEET 3: SEVERAL NOTES INDICATE TO SEE THE "RAMADA MANURACTURER'S RECOMMENDATIONS" FOR VARIOUS ELEMENTS. PROVIDE THOSE ON THE DRAWINGS.
7. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
06/30/2011 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
06/30/2011 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Passed
06/30/2011 ROBERT SHERRY WATER REVIEW Approved
07/11/2011 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
07/13/2011 DELMA ROBEY OUT TO CUSTOMER Completed