Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - TI ALL
Permit Number - T11CM01588
Review Name: RESUBMITTAL - TI ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/31/2011 | RONALD BROWN | ADA | REVIEW | Passed | |
| 09/01/2011 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 09/06/2011 | DAVE MANN | FIRE | REVIEW | Approved | |
| 09/07/2011 | JASON GREEN | ENGINEERING | REVIEW | Approved | Building Only |
| 09/09/2011 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Comment not resolved. The proposed 3" diameter openings located in two sides of each collector box do not have the same flow capacity as the minimum required scupper. The openings act as weirs, not vertical pipes (or horizontal pipes running full) and the pipe sizes obtained from Table 1106.2 or Table 1106.3, IPC 2006 are not correct. In addition, the projected roof area you provide does not appear to include the effect of surrounding vertical walls (i.e. parapets) that can divert rain onto the roof (Section 1106.4, IPC 2006). [Original comment: Provide calculations to show that the size of the two overflow openings in the roof drain collector boxes have a drainage capacity equal to the minimum required scupper size. Reference: Section 1107.1, IPC 2006.] |
| 09/09/2011 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 09/09/2011 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 09/09/2011 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 09/12/2011 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 09/12/2011 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Approv-Cond | Reference plumbing for overflow flow drain comments. |
| 09/12/2011 | RONALD BROWN | ZONING HC | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/13/2011 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 09/13/2011 | SUE REEVES | REJECT SHELF | Completed |