Permit Number: T11BU01211
Parcel: 132130720

Review Status: Completed

Review Details: GRADING

Permit Number - T11BU01211
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/05/2011 GERRY KOZIOL WWM REVIEW Approved
10/07/2011 ELIZABETH LEIBOLD ENGINEERING REVIEW Denied DATE: October 7, 2011
SUBJECT: Tucson Marketplace Wal-Mart Grading Plan Engineering Review
REVIEWER: Elizabeth Leibold, P.E.
ACTIVITY NUMBER: T11BU01211
LOCATION: FEMA 1636K X-Unshaded

SUMMARY: Engineering has received and reviewed the Bridges Wal-Mart grading plans. T11BU00616 is the rough grading permit which has been issued for the Phase 2 Tucson Marketplace. A separate grading permit application will be needed for the spine road private street for inspection purposes. This grading permit T11BU01211 for the Wal-Mart pad finish grading is required prior to issuance of building plans. Engineering approval for the grading plan set for the new Wal-Mart is not recommended until the following comments are addressed.

COMMENTS:
1) DS Sec.3-01.3.3.B.5: On sheets SP1 & SP2 the bollards are labeled at 5-ft OC and 6-ft OC. In response letter, explain how physical separation is achieved between vehicular area and the pedestrian access areas, or revise plans.
2) DS Sec.3-05.2.3.C: Revise sidewalk width along the northwest side of the building, or show wheel stops at adjacent parking spaces that provide the minimum 4-ft clear for vehicular overhang conditions.
3) Tucson Code Sec. 26-6.2: Address the following easement comments:
a) Provide dkt/pg for all easements.
b) Revise plans to show that no waterharvesting, swales, or ponding are located on top of utility lines.
c) Check plans and provide cross sections to clarify that no cut/fill more than a foot is proposed without utility authorization(s).
d) Label locations of depressed curb or other access points for utility easement access at south side of building.
4) DS Sec.2-02.2.1.A.29: Please add Development Plan D11-0001 and permit number T11CM02899 to cover sheet.

For any questions, call me at 837-4934.

Elizabeth Leibold, P.E., CPM, CFM
Civil Engineer
Engineering Division
Planning & Development Services
10/07/2011 MICHAEL ST. PAUL ZONING REVIEW Denied October 7, 2011

Development Services Department
Zoning Review Section

Michael St.Paul
Planning Technician

T11BU01211 Grading Plans for T11CM02899

1260 E Tucson Marketplace Blvd


Comments:

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed.

2. We cannot verify that the grading plan is in compliance with an approved site plan for this site. The site plan has not yet been approved. Please provide one copy of the stamped approved site plan with your next submittal.

3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved site plan. Additional comments may be forthcoming.
10/17/2011 ANDREW CONNOR NPPO REVIEW Denied Ensure that all Engineering comments and concerns are addressed prior NPP / Landscape approval stamp.

Final Status

Task End Date Reviewer's Name Type of Review Description
10/21/2011 GERARDO BONILLA OUT TO CUSTOMER Completed
10/21/2011 SUE REEVES REJECT SHELF Completed