Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T10OT01972
Parcel: 12416017A

Address:
602 E 22ND ST

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T10OT01972
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/15/2010 JASON GREEN ENGINEERING REVIEW Approved September 15, 2010
FLOODPLAIN USE PERMIT NO.: T10OT01972
ADDRESS: 602 E 22nd St Tucson, Arizona 85713
PROPERTY OWNER: Child Parent Centers, Inc.
602 E 22nd St Tucson, Arizona 85713

The applicant is authorized to use a portion of the City of Tucson Flood Hazard Area per the 18th Street Wash delineation, specifically described as:

A portion of Parcel 124-16-017A, BRUCKNERS LOTS 1 TO 8 INCL BLK 3

For the purpose of a tenant improvement to an existing non-conforming structure.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

This floodplain use permit is issued with the following 13 conditions:
1) All improvements proposed under this permit will be cumulative in percentage, to include this project.
2) The proposed improvements shall not impose conditions that would increase the flood damage potential to the combined proposed and existing building, by 50 percent or greater of the existing structure's value.
3) A cost estimate was provided showing that the improvements are less than 50 % (estimate was 7.1%) of the assessed value ($842,062), as shown on the Pima County Assessors Website. No person shall repair or alter property in a piecemeal manner so as to avoid the provisions of Section 26-4.1.a.3, Chapter 26-Tucson Code. The estimate will be recorded and if piecemeal permits for this construction are applied for the cost estimate will be added to it.
4) All work shall conform to the approved Details and General site plan sheets which are made part of this permit.
5) This project is located in a City of Tucson Flood Hazard Area per the City of Tucson Mapguide Floodplain delineation of 18th Street Wash.
6) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
7) This Floodplain Use Permit is issued concurrently with the improvement plans/permit. Copies of these documents shall be kept in a readily accessible location on site at all times.
8) Any future permanent, freestanding walls or other structures shall have separate floodplain use permit applications submitted to this office for review and approval.
9) An application/processing fee of $50.00 (submittal fee) must accompany each future request for work to be authorized under this floodplain use permit. Engineering study review fees of $150.00 may be imposed based upon the fee schedule in the current floodplain ordinance.
10) The associated improvements are with permit activity number T10CM02562.
11) The applicant attests to the fact that the plans and documents submitted represent all of the improvements that will be done to the existing building, and that all additions, improvements or repairs to the building are included in the construction plans and/or documents herewith. No other improvements, repairs, reconstruction, additions or remodeling have been made to the structure that is not indicated in the attached plans and/or documents.
12) Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. This permit may be renewed for up to one year at the sole discretion of the City Engineer or designated representatives.
13) This permit is specific to the improvements for 602 E 22nd Street as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.

Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. This permit may be renewed for up to one year, in the absence of Registered Plant authorization, at the sole discretion of the City Engineer or designated representatives.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.

APPLICANT NAME: Mirek Edward
ADDRESS: 4229 E Seneca Street Tucson, Arizona 85712
PHONE: 520-318-3180
OWNER: Child Parent Centers, Inc.
ADDRESS: 602 e 22nd Street Tucson, Arizona 85713
PHONE: 520-623-2512

(EXPIRATION DATE) Month: _09 Day: 13 Year: 2011

SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.

Final Status

Task End Date Reviewer's Name Type of Review Description
10/12/2010 CPIERCE1 OUT TO CUSTOMER Completed