Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T10CM02832
Parcel: 133250540

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T10CM02832
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/20/2010 BEV HESTER ENGINEERING REVIEW Approved
10/22/2010 GERRY KOZIOL WWM REVIEW Approved
11/09/2010 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Denied T10CM02832
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the notated items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:
Show corrections and revisions on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and notate sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review.

All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration.

GENERAL NOTES:

Limit all code references to those recognized by the City of Tucson. Adopted 2006 codes are listed at the Planning & Development Services web site. Revise the 2003 code references at General Keynote #3, 4 & 6 on sheet A-1.

FOUNDATION PLANS:

1. Show available Alternate Braced Wall Panel devices for providing the required 1800 LBS uplift capacity, R602.10.6. Revise HD2A holdown on sheet S-2.

FLOOR PLANS:

1. Show a ½" gypsum board (garage side) on all walls common to the garage and house or other fire rated product in compliance with R309.2.
2. Show the location of a minimum 22" x 30" attic access. Attic access is required for areas exceeding 30 SQ FT with a minimum of 30" of headroom and located in a hallway or readily accessible space, R807.1.

STRUCTURAL PLANS:

1. Remove the undersized H-4A beam option for the garage opening on sheet S-3, R301.1.
2. Provide the steel lintel Engineered Data notated on sheet S-3, R606.10.

SECTIONS - DETAILS:

1. Clarify the overtyped Braced Wall Panel notation (under Sheathing:) on sheet S-2, R106.1.1.
2. Show fiber-cement board or glass mat gypsum backers for tiled walls in tub and shower areas, R702.4.2.
3. Show compliance with R806.4 by stating "no vapor retarders at the ceiling" for roofs without vented attic space.

MECHANICAL PLANS:

1. Show impact protection for appliances located in the garage, M1307.3.1.
2. Show dryer vent size and location for venting to exterior, M1501.
3. Show bathroom exhaust fan locations for venting to exterior with minimum 50 CFM rating R303.3 and M1507.3.
4. Show the kitchen exhaust fan minimum 100 CFM rating, M1507.3.
5. Provide return air duct and register sizes meeting minimum requirements of 72 SQ IN/ ton, M1602. Minimum duct/register size: heat pump or air conditioner - 6 SQ IN per 1,000 BTU, M1403.1 (1 ton cooling = 12,000 BTU). The 16" x 16" return air duct is undersized. Show a minimum 288 SQ. IN. duct size.

ELECTRICAL PLANS:

1. Smoke alarms are required outside each separate sleeping area, R313.2. Show a smoke alarm on the outside of the Master Bedroom door.
2. Show or notate a disconnect means or a locking breaker for the water heater, E4001.5.

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
11/19/2010 DELMA ROBEY OUT TO CUSTOMER Completed
11/19/2010 SUE REEVES REJECT SHELF Completed