Permit Number: T10CM02085
Parcel: 205640620

Review Status: Completed

Review Details: COMMERCIAL NEW

Permit Number - T10CM02085
Review Name: COMMERCIAL NEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/11/2010 MARTIN BROWN FIRE REVIEW Approved
08/16/2010 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. STRUCTURAL CALCULATIONS; PAGE 1: UNDER 'LATERAL LOADS (WIND LOADS) THE 2003 IBC IS REFERENCED. REVISE TO THE 2006 IBC AND REVIEW CALCULATIONS FOR CONFORMANCE TO THAT CODE.
2. SHEET S1 (SECTION 1); STRUCTURAL CALCULATIONS (PAGE 4): THE STRUCTURAL CALCULATIONS INDICATE THE REINFORCING IN THE BOTTOM SLAB OF THE WET WELL TO BE #5 AT 10" EW TOP AND #5 AT 12" EW BOTTOM, WHILE THE SECTION 1 INDICATES #5 AT 12" EW TOP AND BOTTOM. CLARIFY.
3. SHEET S1; SECTION 1: THE PRECAST WET WELL WALLS WILL BE A DEFERRED SUBMITTAL. ALL DEFERRED SUBMITTALS MUST BE APPROVED IN WRITING BY LEERAY HANLY BEFORE THOSE SUBMITTALS WILL BE REVIEWED (LEERAY.HANLY@TUCSONAZ.GOV).
4. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
08/23/2010 ROBERT SHERRY WATER REVIEW Approved
08/23/2010 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Passed
08/23/2010 LAITH ALSHAMI ENGINEERING REVIEW Approved
08/24/2010 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
08/30/2010 STEVE SHIELDS ZONING REVIEW Approved
09/09/2010 GERRY KOZIOL WWM REVIEW Denied 1. NEEDS WW DESIGN REVIEW OF LIFT STATION 3RD FLOOR BY KURT STEMM 740-6607
09/13/2010 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
09/16/2010 DELMA ROBEY OUT TO CUSTOMER Completed