Permit Number: T10CM00488
Parcel: 115160320

Review Status: Completed

Review Details: COMMERCIAL TI

Permit Number - T10CM00488
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/01/2010 DAVE MANN FIRE REVIEW Approved
03/01/2010 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied Provide information on the sequence of operation for the restroom exhaust fans to show that all of the air supplied to the restrooms will be exhausted. Reference: Section 403.2.1 (3), IMC 2006.
03/01/2010 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved
03/01/2010 ROBERT SHERRY WATER REVIEW Approved
03/01/2010 RONALD BROWN BUILDING-COMMERCIAL REVIEW Approved
03/01/2010 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied Clarify how the drain piping will be modified for the installation of P-5 (i.e. provide a riser diagram). Note that a service sink requires a minimum 2" trap and trap arm.
03/01/2010 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
03/01/2010 RONALD BROWN ADA REVIEW Passed
03/01/2010 RONALD BROWN ZONING HC REVIEW Approved
03/04/2010 CAGUILA1 WWM REVIEW Needs Review
03/04/2010 MICHAEL ST. PAUL ZONING REVIEW Approved
03/04/2010 JASON GREEN ENGINEERING REVIEW Approved March 4, 2010
FLOODPLAIN USE PERMIT NO.: T10OT00489
ADDRESS: 1141 W Grant Road Tucson Arizona 85712
PROPERTY OWNER: Sloat Family Partnership
1100 N Wilmot Road, Tucson AZ 85710

The applicant is authorized to use a portion of the City of Tucson Flood Hazard Area per the Kruger Wash delineation, specifically described as:

A portion of Parcel 115-16-0320, GRANT INTERSTATE COMMONS LOT 0004

For the purpose of a tenant improvement to an existing non-conforming structure.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

This floodplain use permit is issued with the following 13 conditions:
1) All improvements proposed under this permit will be cumulative in percentage, to include this project.
2) The proposed improvements shall not impose conditions that would increase the flood damage potential to the combined proposed and existing building, by 50 percent or greater of the existing structure's value.
3) A cost estimate was provided showing that the improvements are less than 50 % (estimate was 5%) of the assessed value ($1,328,333), as shown on the Pima County Assessors Website. No person shall repair or alter property in a piecemeal manner so as to avoid the provisions of Section 26-4.1.a.3, Chapter 26-Tucson Code. The estimate will be recorded and if piecemeal permits for this construction are applied for the cost estimate will be added to it.
4) All work shall conform to the approved Details and General site plan sheets which are made part of this permit.
5) This project is located in a City of Tucson Flood Hazard Area per the City of Tucson Mapguide Floodplain delineation of Kruger Wash.
6) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
7) This Floodplain Use Permit is issued concurrently with the improvement plans/permit. Copies of these documents shall be kept in a readily accessible location on site at all times.
8) Any future permanent, freestanding walls or other structures shall have separate floodplain use permit applications submitted to this office for review and approval.
9) An application/processing fee of $50.00 (submittal fee) must accompany each future request for work to be authorized under this floodplain use permit. Engineering study review fees of $150.00 may be imposed based upon the fee schedule in the current floodplain ordinance.
10) The associated improvements are with permit activity number T10CM00488
11) The applicant attests to the fact that the plans and documents submitted represent all of the improvements that will be done to the existing building, and that all additions, improvements or repairs to the building are included in the construction plans and/or documents herewith. No other improvements, repairs, reconstruction, additions or remodeling have been made to the structure that is not indicated in the attached plans and/or documents.
12) Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. This permit may be renewed for up to one year at the sole discretion of the City Engineer or designated representatives.
13) This permit is specific to the improvements for 1141 W Grant Road as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.

Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. This permit may be renewed for up to one year, in the absence of Registered Plant authorization, at the sole discretion of the City Engineer or designated representatives.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.

APPLICANT NAME: Caylor CoOnstruction
ADDRESS: 6422 E Speedway Blvd, Tucson AZ 85710
PHONE: 520-298-2200
OWNER: Sloat Family Partnership
ADDRESS: 1100 N Wilmot Rd, Tucson AZ 85710
PHONE: 520-Unknown

(EXPIRATION DATE) Month: _03 Day: 04 Year: 2011

SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.