Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T10CM00311
Parcel: 11504492A

Address:
901 E 1ST ST

Review Status: Completed

Review Details: SITE

Permit Number - T10CM00311
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/18/2010 MARTIN BROWN FIRE REVIEW Denied Fire sprinklers will be required.
Show location of existing fire hydrants, with dimensions to property lines.
02/19/2010 ANDREW CONNOR NPPO REVIEW Approved
02/19/2010 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. Submit previously approved site and landscape plan for reference.

2. Additional comments may apply.
02/22/2010 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Islamic Center of Tucson, Classroom Addition
T10CM00311
Site Plan (1st Review)

TRANSMITTAL DATE: February 22, 2010

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC). Based on the building expansion calculation provided on the site plan the review is for full code compliance for the area of expansion only. Once the last approved site plan is provided the building expansion calculation can be verified. Additional comments may be forth coming.

2. Provide a copy of the last approve site plan with your next submittal.

3. D.S. 2-02.2.1.A.6 For all existing and proposed buildings and structures, include size, height, overhangs, canopies, and use on the site plan.

4. D.S. 2-02.2.1.A.7 Per LUC Section 3.2.6.4, Development Designator "18", Perimeter Yard Indicator "CC" the proposed addition does not meet the required perimeter yard setback of the height of proposed exterior building wall to the east property line. Based on the elevation provided on sheet 2 the height of the exterior building wall is 9'-0" there for a 9'-0" perimeter yard is required, 6'-0" provided. A Design Development Option (DDO) is requried.

5. D.S. 2-02.2.1.A.10 Show sight visibility triangles (SVTs) on the plan.

6. D.S. 2-02.2.1.A.13 If applicable show the location, type, size, and height of existing and proposed signage on the plan.

7. D.S. 2-02.2.1.A.20 If applicable show all easements of record on the plan along with the recordation information, docket and page.

8. D.S. 2-02.2.1.A.25 If applicable show the existing and proposed site lighting on the plan.

9. D.S. 2-02.2.1.A.28 Provide the existing zoning for the parcels located south of 1st Street.

10. D.S. 2-02.2.1.A.31 Provide the existing and proposed use on the site plan. The use should reflect a use shown with in the LUC such as Religious Use "18"

The following calculations are required on the site plan:

11. D.S. 2-02.2.2.A.4 Provide the parking variance date of approval, what was approved and any conditions on the site plan. Provide a copy of the parking variance C10-88-42 with your next submittal.
12. D.S. 2-02.2.2.A.4 Provide a vehicle parking calculation referencing the variance on the plan.
13. Depending on how the above comments are addressed addition comments may be forth coming.
If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\site\t10cm00311

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents.
02/23/2010 RICK MYERS PLUMBING-COMMERCIAL REVIEW Denied Revise the site drawing to include the following information:
a. the location and size of the water meter
b. the location of the main water lines and fire hydrants
c. the location of the gas meter
d. the location and size of the public sanitary sewer and
e. the location, invert, and rim elevation of all manholes and cleanouts.
Reference: City of Tucson Development Standard No. 2-01.1.0 2 3.8 D and Section 103.2.3, UPC 2006.
03/11/2010 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, Engineering and Floodplain Review, 03/11/2010,

Site Plan:

Provide the following information:

1. Existing sight visibility triangles (D.S. 2-02.2.1.A.10).
2. Site drainage patterns including the roof drainage, the building finish floor elevation and the site finish grades (D.S. 2-02.2.1.A.16).
3. The estimated cut and fill quantities. If quantities are zeros, indicate that on the plan (D.S. 2-02.2.1.A.17).
4. Graphical depiction of all easements of record including recording docket and page reference (D.S. 2-02.2.1.A.20).
5. Dimensions from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines (D.S. 2-02.2.1.A.21).
6. Existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number (D.S. 2-02.2.1.A.23).
7. Refuse container location, size, and access thereto fully dimensioned (D.S. 2-02.2.1.A.32).


Resubmittal Required: Revised Site Plan

Final Status

Task End Date Reviewer's Name Type of Review Description
06/11/2010 DELMA ROBEY OUT TO CUSTOMER Completed
06/11/2010 SUE REEVES REJECT SHELF Completed