Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T09CM03166
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/12/2010 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 1-12-10 Activity: T09CM03166 Address: 627 N Norton Ave Applicant: Bill Clark Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. FLOOR PLANS: 2. Provide emergency escape/rescue opening from basement that opens directly into a public street, public alley, yard or court, R310.1. STRUCTURAL PLANS: 3. Provide detail for mechanical duct penetration through existing basement wall that includes opening reinforcement and potential surcharge from new structure, R601.2. PLUMBING PLAN: 4. Provide waste clean out for bathroom #2, UPC 707.4. 5. Provide vent for water closet in bathroom #2 and lavatories in master bathroom, UPC 904. 6. Size the gas line to the roof-mounted gas pack according to Table 12-8. 7. Provide note requiring that water hammer arrestors be installed in accordance with ASSE 1010-2004 on water lines serving appliances equipped with quick-closing valves to include but not limited to: clothes washers, dishwashers, and refrigerators, UPC 609.10. 8. Specify water conservation requirements: Water closets = 1.6 gallons per flush, Sinks/ Showerheads = 3 gpm, UPC State Amend. 45-312. 9. Shower and tub/shower combinations that have individual control valves shall be of the pressure balance or thermostatic mixing valve type. MECHANICAL PLAN: 10. Show supply and return air ducts with a minimum R-8 insulation when located outside the thermal envelope, R1103.2.1. ELECTRICAL PLAN: 11. Specify location of sub panel (existing service panel) and provide adequate working clearance (30"x36") E3305.2, E3501.6.2. 12. Air conditioning loads must be added to the electrical load calculation at 100% of the nameplate rating, E3502.2. 13. Provide a 20-amp branch circuit for bathroom receptacles that serve no other outlets, E3603.4. 14. Provide note for location of smoke detectors in accordance with NFPA 72 for proximity to forced air registers, R313.1. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
| 12/17/2009 | GERRY KOZIOL | WWM | REVIEW | Denied | NEED 5TH FLOOR WASTEWATER CREDIT EVALUATION |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/13/2010 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 01/13/2010 | SUE REEVES | REJECT SHELF | Completed |