Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T09CM03054
Parcel: 125020460

Address:
2802 E 1ST ST

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T09CM03054
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/04/2010 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS
Date: 1-05-09
Activity: T09CM03054
Address: 2802 E 1st St
Applicant: Cassie Cuffman

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:
1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets.

SITE PLAN:
2. Specify the location of the new sewer connection to the existing line, R106.1.1.

FLOOR PLANS:
3. Specify the access location to the new water heater and provide fuel or power source to unit, M2001.1.
4. Identify ceiling heights in all areas. Note average height at sloped ceiling areas, R305.1.

FOUNDATION PLANS:
5. Landing or floor surface required at all exterior doors, R311.4.3. Specify the height of the exterior floor surface when the door swings over the landing, R311.4.3.1.
6.
STRUCTURAL PLANS:
7. Provide a complete braced wall panel layout showing panels at the ends (within 12.5') of all wall lines and additional panels centered at least every 25' between, Table R602.10.1.
8. Provide a header schedule consistent with Table 502.5(1) or specify size of steel lintels.

ELEVATIONS:
9. Provide exterior elevation drawings for the proposed project.

SECTIONS - DETAILS:
10. Standard R-30 batt insulation is 9.5" and the proposed roof framing members are 11.25". Provide full cavity insulation or ventilate the remaining air-space, R806.2.
11. Specify anchor-bolt spacing, R403.1.6.
12. For thin-coat stucco systems, indicate the ICC ESR #, system name, and vapor barrier, R703.6.

PLUMBING PLAN:
13. Provide the maximum developed length of water line from the meter the furthest appliance served, the available water pressure, and the diameter of the water service line, P2903.7.
14. Provide a water fixture unit schedule for the entire property (including existing) P2903.6.
15. The Tucson Water policy adopted 3/2/07 limits the maximum demand for a 5/8" water meter (there are no ¾" meters for Tucson Water service) to 10 GPM; confirm with Tucson Water that the existing meter will be able to meet the new water demand. Reference Tables P2903.6 and P2903.6 (1), IRC 2006.
16. Provide pressure and temperature relief valve for the water heater terminating to the exterior facing no more than 6 above the floor, P2803.6.1.
17. Specify the water conservation requirements: Water closets = 1.6 gallons per flush, Sinks = 2.2 gpm, Showerheads = 2.5 gpm, P2903.2.
18. Vent piping diameter shall not be less than one-half the size of the drain served (3/4" VTR?), P3113.1.

MECHANICAL PLAN:
19. Provide a mechanical equipment specification list, M1302.1.
20. Show supply and return air ducts with a minimum R-8 insulation when located outside the thermal envelope, R1103.2.1.
21. Provide size of return air ducts and register sizes, M1602. Minimum duct/register size: heat pump or air conditioner - 6 sq. in. / 1000 BTU, M1403.1 (1 ton cooling = 12,000 BTU).

ELECTRICAL PLAN:
22. Designate the circuit number for each light fixture, receptacle, appliance, and equip disconnect on the electrical layout, E3603.5.
23. At least one wall switch controlled light must be provided at outdoor entrances or exits, E3803.3.
24. Provide electrical load calculations for determining the service panel size to accommodate the sub-panel upgrade and new roof-mounted heat pump, E3502.2.

INTERNATIONAL ENERGY CONSERVATION CODE:
25. Specify the "U" factor and the solar heat gain coefficient of the windows and doors, N1102.1.

If you have any questions please contact:
Clayton Trevillyan
520.837.4913
Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
01/07/2010 CINDY AGUILAR OUT TO CUSTOMER Completed
01/07/2010 SUE REEVES REJECT SHELF Completed